FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Technical Bulletin
All
|
Description of BS EN 62040-3:2001 2010This standard applies to electronic indirect a.c. converter systems with electrical energy storage means in the d.c. link. The primary function of the uninterruptible power system (UPS) covered by this standard is to ensure continuity of an alternating power source. The uninterruptible power system may also serve to improve the quality of the power source by keeping it within specified characteristics. A variety of uninterruptible power systems have been developed to meet consumers' requirements for continuity and quality of power for different types of loads over a wide range of power, from less than 100 W to several megawatts. Refer to annexes A and B for information on some of the types available. This standard applies to electronic uninterruptible power systems (UPS):
This standard also includes the method of specifying all power switches that form integral parts of a UPS and are associated with its output. Included are interrupters, bypass switches, isolating switches, load transfer switches and tie switches. These switches interact with other functional units of the UPS to maintain continuity of load power. This standard does not refer to conventional mains distribution boards, rectifier input switches or d.c. switches (for example for batteries, rectifier output or inverter input, etc.), or UPS based on rotating machines.
Under current technology, the majority of UPS load equipment employs power supplies which present a non-linear load to the UPS and can be tolerant of non-sinusoidal voltage waveforms for a limited time duration. UPS output ratings are specified to be compatible with non-linear loading and linear loading, subject to manufacturers' declaration if different. References within this standard to linear loading are retained for test method reasons, or validation of manufacturers' additional declaration.
This standard is intended to define a complete uninterruptible power system in terms of its performance and not individual UPS functional units. The individual UPS functional units are dealt with in the IEC publications referred to in the bibliography given in annex I, which apply in so far as they are not in contradiction with this standard.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |