Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(317)
(572)
(43)
(234)
(969)
(643)
(2114)
(64)
(92448)
(54)
(535)
(117)
(31)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6217)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • NFPA
    NFPA 56: Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems
    This title can only be subscribed to with another NFPA title (See details)
    Edition: 2020
    $213.60
    / user per year

Content Description

Per NFPA's requirements, when purchasing NFPA 2021 Standards and/or 2020 NFPA 70 (NEC), you must subscribe to at least one more NFPA Standard to complete your purchase. In order to fulfill this requirement, we automatically add 2019 NFPA 900 to your cart. This title may be removed during checkout if you choose to add a different NFPA standard to your cart, and pricing will be recalculated accordingly.
Help ensure you and your team are up to date with the latest safety criteria for flammable gas piping system cleaning and purging procedures. There are significant risks of injury and loss if proper protocols are not adhered to when cleaning and purging piping systems used for transporting flammable substances. Originally developed at the request of the U.S. Chemical Safety Board (CSB) in recognition of the inherent dangers, NFPA 56, Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems, 2020 edition, offers essential requirements for developing safe operating procedures. This standard is the industry benchmark for helping safeguard personnel and facilities from risks of fire and explosions during pipe system maintenance. From notifying and training personnel involved in cleaning and purging operations to identifying a safe discharge point and preventing the development of a flammable gas mixture in occupied areas, NFPA 56 provides information and requirements that everyone at your facility can apply to better avoid incidents and help protect lives and property. Provisions apply to electric-generating plants and in industrial, institutional, and commercial applications including: Cleaning new or existing piping systems Purging piping systems into service Purging piping systems out of service The 2020 edition features critical updates that may impact your work and the safety of your facility. The revised NFPA 56 offers comprehensive requirements for acceptable safety protocols for charging and evacuating flammable gas piping systems. The standard is updated to reflect the most current industry knowledge and best practices. Notable changes include: Further specification to where the standard is not applicable, including gas-consuming equipment and gathering lines from well pads to gas processing facilities, because these systems are addressed in other publications; and well padding systems, because of the complexity and range of issues that make NFPA 56 inadequate for this type of application Revised cleaning and purging activities in Chapter 4 Added associated guidance information in Annex A to address gaps within requirements that were identified in the previous edition Added guidance information to Annex A to provide guidelines for the development of an emergency response plan (ERP), assist in developing a comprehensive training program, and verify that personnel can perform their duties prior to the start of the cleaning or purging activity Updated extracts from other NFPA documents to the latest revisions of their source documents Revised information in Annex B extracted from the AGA Purging Manual to be consistent with the latest edition of the publication Get the knowledge to help make the right decisions and establish practices for maximizing safety.

The following editions for this book are also available...

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
NFPA
[+] $2,390.85 Buy
VAR
NFPA
[+] $1,081.86 Buy
VAR
NFPA
[+] $2,656.50 Buy

Subscription Information

MADCAD.com NFPA subscriptions are annual and access is concurrency based (number of people that can access the subscription at any given time).

 

Some features of MADCAD.com NFPA Subscriptions are:

 

- Floating concurrency model: Set your concurrency level and share your NFPA Subscriptions among your offices enterprise-wide.

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access NFPA Standards from any browser on your computer, tablet or smart phone.

- Customized Subscriptions: Select different number of concurrencies based on your needs. Set higher number of seats for more used NFPA Subscriptions and lower seats on standards with less need.

 

- Immediate Access: As soon as the transaction is completed, your NFPA Subscription will be ready for access.

 

For any further information on MADCAD.com NFPA Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About NFPA

The mission of the international nonprofit NFPA, established in 1896, is to reduce the worldwide burden of fire and other hazards on the quality of life by providing and advocating consensus codes and standards, research, training, and education.

 

The world's leading advocate of fire prevention and an authoritative source on public safety, NFPA develops, publishes, and disseminates more than 300 consensus codes and standards intended to minimize the possibility and effects of fire and other risks.

 

NFPA membership totals more than 70,000 individuals around the world

 

X