Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(573)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(541)
(117)
(33)
(20)
(19)
(93277)
(3)
(17)
(1)
(351)
(300)
(6217)
(240)
(16)
(5)
(1621)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • BSI
    PD 6591:1996, CENELEC Report R110-003:1995 Guidelines on how to use anechoic enclosures that do not fulfil the requirements regarding normalized site attenuation for pre-compliance tests of products
    Edition: 1996
    $411.69
    / user per year

Description of PD 6591:1996 1996

This guideline deals with the application of absorber-lined enclosures for radiated-emission tests according to CISPR 16 [1], CISPR 11 [2], CISPR 22 [3] and EN 50147-2 [4] in the frequency range of 30 - 1000 MHz.

Standard site acceptability criteria based on normalized site attenuation (NSA) measurements are given in [1, 4]. The chamber factor concept shall provide a method for more detailed evaluations of the performance characteristics of enclosures. Measured chamber factor data can, furthermore, be used to correlate test results from equipment under test (EUT) to open site results. Whereas NSA evaluates chamber performance with respect to theoretically calculated reference values, chamber factors are derived from comparative measurements between an enclosure and a good reference site.

If the measured site attenuation exceeds the “± 4 dB”-limit only in the frequency range of 30 - 200 MHz and by not more than ± 12 dB, then the methods described in this report may be applied. For equipment that is no larger than half a wavelength (including cables) the enclosure can then be used at the expense of higher test uncertainty in the lower frequency range.



About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X