Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(317)
(572)
(43)
(234)
(969)
(643)
(2114)
(64)
(92448)
(54)
(535)
(117)
(31)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6023)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • BSI
    BS ISO 10303-32:1998 Industrial automation systems and integration. Product data representation and exchange - Conformance testing methodology and framework: Requirements on testing laboratories and clients
    Edition: 1998
    $418.55
    / user per year

Description of BS ISO 10303-32:1998 1998

This part of ISO 10303 specifies the techniques for conformance testing and the means to facilitate the use of those techniques by the testing laboratory and the client. This part of ISO 10303 specifies the roles of both the testing laboratory and the client during the conformance assessment process, the need to reach mutual agreements between them, and the requirements on each of them.

1.1 Coverage

The following are within the scope of this part of ISO 10303:

  • general requirements on the testing laboratory and on the client that are applicable to the conformance assessment process;

  • the exchange of technical and administrative information, including a protocol implementation conformance statement (PICS) and a protocol implementation extra information for testing (PIXIT);

  • the process of negotiation between the testing laboratory and the client to reach an agreement on:

    1. the definition of the implementation under test (IUT);

    2. the abstract test method and abstract test suite to be used;

    3. the conditions under which conformance testing will be performed;

  • requirements for the structure and content of the test report that document the results of the conformance testing.

The following are outside the scope of this part of ISO 10303:

  • the resolution of technical issues between the client and the testing laboratory that arise during the conformance assessment process;

  • the production of diagnostic information in addition to the conformance log and conformance test report;

  • any aspects that are not specific to the conformance testing of implementations of ISO 10303 application protocols;

  • the certification and testing laboratory accreditation processes.

NOTE - Information on requirements on the testing laboratory and the client with respect to certification are given in annex D. Roles of accreditation and certification organisations are given in annex D of ISO 10303-31.

1.2 Applicability

This part of ISO 10303 applies to the conformance testing of any implementation of an ISO 10303 application protocol. The application protocols for which abstract test suites are specified are defined in the ISO 10303-200 series. The abstract test suites are specified in the ISO 10303-300 series. Conformance testing of an implementation is based on the use of an abstract test suite together with an abstract test method in accordance with ISO 10303-34.

The testing laboratory is responsible for conducting the conformance testing of an implementation of ISO 10303 at the request of a client. A testing laboratory may be any of the following:

  • organisations developing or supplying implementations of ISO 10303;

NOTE 1 - Referred to as implementors.

  • organisations verifying implementations of ISO 10303 for their own use;

NOTE 2 - Referred to as users.

  • organisations who are independent of suppliers or users of implementations of ISO 10303, and whose business is the testing of such implementations.

NOTE 3 - Referred to as testing laboratories.

This part of ISO 10303 applies equally to those testing laboratories that are affiliated to suppliers or procurers, and those that are independent of suppliers and procurers.

Clients may be:

  • implementors or suppliers of systems using ISO 10303, who are applying for their implementations to be tested;

  • organisations that procure those implementations;

  • any other interested party.

This part of ISO 10303 applies equally to all three types of clients.



About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X