Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(317)
(572)
(43)
(234)
(969)
(643)
(2114)
(64)
(92448)
(54)
(535)
(117)
(31)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6023)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • BSI
    BS EN ISO 80601-2-84:2023 Medical electrical equipment - Particular requirements for the basic safety and essential performance of ventilators for the emergency medical services environment
    Edition: 2023
    $641.56
    / user per year

Description of BS EN ISO 80601-2-84:2023 2023

This document applies to the basic safety and essential performance of an EMS ventilator in combination with its accessories, hereafter also referred to as ME equipment: ¾     intended for patients who need differing levels of support from artificial ventilation including ventilator-dependent patients; ¾     intended to be operated by a healthcare professional operator; ¾     intended for use in the EMS environment; and ¾     intended for invasive or non-invasive ventilation. NOTE 2     An EMS ventilator can also be used for transport within a professional healthcare facility. An EMS ventilator is not considered to use a physiologic closed loop-control system unless it uses a physiological patient variable to adjust the  artificial ventilation therapy settings. This document is also applicable to those accessories intended by their manufacturer to be connected to the ventilator breathing system, or to an EMS ventilator, where the characteristics of those accessories can affect the basic safety or essential performance of the EMS ventilator. NOTE 3     If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601?1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1. NOTE 4     Additional information can be found in IEC 60601-1:2005+AMD1:2012+AMD2:2020, 4.2. This document does not specify the requirements for the following: NOTE 5     See ISO/TR 21954 for guidance on the selection of the appropriate ventilator for a given patient.  ¾     ventilators or accessories intended for ventilator-dependent patients in critical care applications, which are given in ISO 80601-2-12. ¾     ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601-2-72. ¾     ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601?2?13. ¾     ventilators or accessories intended for ventilatory support equipment (intended only to augment the ventilation of spontaneously breathing patients), which are given in ISO 80601?2-79 and ISO 80601-2-80. ¾     obstructive sleep apnoea therapy ME equipment, which are given in ISO 80601?2?70. ¾     user-powered resuscitators, which are given in ISO 10651?4. ¾     gas-powered emergency resuscitators, which are given in ISO 10651?5. ¾     continuous positive airway pressure (CPAP) ME equipment. ¾     high?frequency jet ventilators (HFJVs), which are given in ISO 80601-2-87. ¾     high?frequency oscillatory ventilators (HFOVs)[44], which are given in ISO 80601-2-87. NOTE 6      An EMS ventilator can incorporate high-frequency jet or high-frequency oscillatory ventilation-modes. ¾     respiratory high-flow therapy equipment, which are given in ISO 80601-2-90. NOTE 7      An EMS ventilator can incorporate high-flow therapy operational mode, but such a mode is only for spontaneously breathing patients. ¾     oxygen therapy constant flow ME equipment. ¾     cuirass or “iron?lung” ventilators.

About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X