Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(572)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(535)
(117)
(33)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6217)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • BSI
    BS EN ISO 80601-2-80:2019 Medical electrical equipment - Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory insufficiency
    Edition: 2019
    $538.63
    / user per year

Description of BS EN ISO 80601-2-80:2019 2019

IEC 60601‑1:2005+AMD1:2012, Clause 1, applies, except as follows:

201.1.1 * Scope

Replacement:

This document applies to the basic safety and essential performance of ventilatory support equipment , as defined in 201.3.205, for ventilatory insufficiency , as defined in 201.3.204, hereafter also referred to as me equipment, in combination with its accessories:

  • intended for use in the home healthcare environment;

  • intended for use by a lay operator;

  • intended for use with patients who have ventilatory insufficiency or failure, the most fragile of which would likely experience injury with the loss of this artificial ventilation;

  • intended for transit-operable use;

  • not intended for patients who are dependent on artificial ventilation for their immediate life support.

EXAMPLE 1 Patients with moderate to severe chronic obstructive pulmonary disease (COPD), moderate amyotrophic lateral sclerosis (ALS), severe bronchopulmonary dysplasia or muscular dystrophy.

NOTE 1 In the home healthcare environment, the supply mains is often not reliable.

NOTE 2 Such ventilatory support equipment can also be used in non-critical care applications of professional health care facilities.

This document is also applicable to those accessories intended by their manufacturer to be connected to the ventilator breathing system of ventilatory support equipment for ventilatory insufficiency , where the characteristics of those accessories can affect the basic safety or essential performance of the ventilatory support equipment for ventilatory insufficiency .

EXAMPLE 2 Breathing sets, connectors, water traps, expiratory valve, humidifier, breathing system filter, external electrical power source, distributed alarm system.

If a clause or subclause is specifically intended to be applicable to me equipment only, or to me systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to me equipment and to me systems, as relevant.

Hazards inherent in the intended physiological function of me equipment or me systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601‑1:2005 +AMD1:2012, 7.2.13 and 8.4.1.

NOTE 3 Additional information can be found in IEC 60601‑1:2005 +AMD1:2012, 4.2.

This document does not specify the requirements for:

  • ventilators or accessories for ventilator-dependent patients intended for critical care applications, which are given in ISO 80601‑2‑12 ;

  • ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601‑2‑13 [5] ;

  • ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601‑2‑84 [6] 4 , the future replacement for ISO 10651‑3 [7] ;

  • ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601‑2‑72 ;

  • ventilatory support equipment or accessories intended for ventilatory impairment , which are given in ISO 80601‑2‑79 [1] ;

  • sleep apnoea therapy me equipment, which are given in ISO 80601‑2‑70 [8] ;

  • continuous positive airway pressure (CPAP) me equipment;

  • high-frequency jet ventilators (HFJVs);

  • high-frequency oscillatory ventilators (HFOVs)[9] ;

  • oxygen therapy constant flow me equipment;

  • cuirass or “iron-lung” ventilation equipment.

This document is a particular standard in the IEC 60601 and IEC/ISO 80601 series of documents.

201.1.2 Object

Replacement:

The object of this document is to establish particular basic safety and essential performance requirements for ventilatory support equipment , as defined in 201.3.205, and its accessories.

NOTE Accessories are included because the combination of the ventilatory support equipment and the accessories needs to be adequately safe. Accessories can have a significant impact on the basic safety or essential performance of the ventilatory support equipment .

201.1.3 Collateral standards

Addition:

This document refers to those applicable collateral standards that are listed in Clause 2 of the general standard and Clause 201.2 of this document.

IEC 60601‑1‑2:2014 , IEC 60601‑1‑6:2010 +AMD1:2013 , IEC 60601‑1‑8:2006 +AMD1:2012 and IEC 60601‑1‑11:2015 apply as modified in Clauses 202, 206, 208 and 211 respectively. IEC 60601‑1‑3 :2008 [10] does not apply. All other published collateral standards in the IEC 60601‑1 series apply as published.

201.1.4 Particular standards

Replacement:

In the IEC 60601 series, particular standards may modify, replace or delete requirements contained in the general standard, including the collateral standards as appropriate for the particular me equipment under consideration, and may add other basic safety or essential performance requirements.

A requirement of a particular standard takes priority over the general standard.

For brevity, IEC 60601‑1:2005 +AMD1:2012 is referred to in this particular document as the general standard. Collateral standards are referred to by their document number.

The numbering of clauses and subclauses of this document corresponds to that of the general standard with the prefix “201” (e.g. 201.1 in this document addresses the content of Clause 1 of the general standard) or applicable collateral standard with the prefix “2xx”, where xx is the final digits of the collateral standard document number (e.g. 202.4 in this document addresses the content of Clause 4 of the IEC 60601‑1‑2 collateral standard, 211.10 in this document addresses the content of Clause 10 of the IEC 60601‑1‑11 collateral standard, etc.). The changes to the text of the general standard are specified by the use of the following words:

"Replacement" means that the clause or subclause of the general standard or applicable collateral standard is replaced completely by the text of this document.

"Addition" means that the text of this document is additional to the requirements of the general standard or applicable collateral standard.

"Amendment" means that the clause or subclause of the general standard or applicable collateral standard is amended as indicated by the text of this document.

Subclauses, figures or tables that are additional to those of the general standard are numbered starting from 201.101. However, due to the fact that definitions in the general standard are numbered 3.1 through 3.147, additional definitions in this document are numbered beginning from 201.3.201. Additional annexes are lettered AA, BB, etc., and additional items aa), bb), etc.

Subclauses, figures or tables which are additional to those of a collateral standard are numbered starting from 20x, where “x” is the number of the collateral standard, e.g. 202 for IEC 60601‑1‑2 , 203 for IEC 60601‑1‑3 , etc.

The term "this document" is used to make reference to the general standard, any applicable collateral standards and this particular document taken together.

Where there is no corresponding clause or subclause in this particular document, the clause or subclause of the general standard or applicable collateral standard, although possibly not relevant, applies without modification; where it is intended that any part of the general standard or applicable collateral standard, although possibly relevant, is not to be applied, a statement to that effect is given in this document.