Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(317)
(572)
(44)
(234)
(969)
(649)
(2114)
(64)
(92448)
(54)
(535)
(117)
(33)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6217)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • BSI
    BS EN 60601-2-63:2015+A1:2019 Medical electrical equipment - Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment
    Edition: 2019
    $497.46
    / user per year

Description of BS EN 60601-2-63:2015+A1:2019 2019

Clause 1 of the general standard 1 applies, except as follows:

201.1.1 Scope

Replacement:

This International Standard applies to the basic safety and essential performance of dental extra-oral X-ray equipment, hereafter also called me equipment. The scope includes me systems containing such me equipment.

NOTE 1 This includes panoramic equipment, cephalometric equipment, and equipment for dental volumetric reconstruction (hereafter DVR) as defined in 201.3.203 below.

NOTE 2 DVR includes dental CBCT (cone beam computed tomography), which is also known with other names in certain parts of the world, e.g. DVT (digital volumetric tomography); DVR also includes tomosynthesis.

NOTE 3 This may include the imaging of other anatomical parts (e.g. the hand) as long as required for dental treatment (e.g. orthodontic treatment).

NOTE 4 This may include anatomical objects of interest to the ENT (ear, nose, and throat) specialist.

The scope of this standard is restricted to X-ray equipment where:

  • the X-ray tube assembly contains the high-voltage transformer assembly and

  • the geometrical relations between the X-ray source, the anatomical object being imaged in the patient, and the X-ray image receptor, are preset in the design and cannot be arbitrarily altered by the operator during intended use.

NOTE 5 dental intra-oral X-ray equipment is excluded from the scope of this standard.

NOTE 6 Focal spot to image receptor distance and focal spot to object distance are preset in the design of dental extra-oral x-ray equipment.

NOTE 7 For dental X-ray equipment not in the scope of this document because of the restriction above, applicable clauses of IEC 60601‑2‑54 may be used with this document.

Me equipment and me systems in the scope of IEC 60601‑2‑44, IEC 60601‑2‑54, IEC 60601‑2‑45, IEC 60601‑2‑65 or IEC 60601‑2‑43 are excluded from the scope of this particular standard. The scope of this International Standard also excludes radiotherapy simulators and equipment for bone or tissue absorption densitometry. Excluded from the scope is also me equipment intended to be used for dental radioscopy.

Within its specific scope, the clauses of this particular standard supersede and replace those of IEC 60601‑2‑7, Medical electrical equipment – Particular requirements for the safety of high-voltage generators of diagnostic X-ray generators and of IEC 60601‑2‑32, Medical electrical equipment – Particular requirements for the safety of associated equipment of X-ray equipment.

NOTE 8 Requirements for X-ray generators and for associated equipment, which were previously specified in IEC 60601‑2‑7 and IEC 60601‑2‑32, have been included in either IEC 60601‑1:2005 (Ed3) or this particular standard. Therefore IEC 60601‑2‑7 and IEC 60601‑2‑32 are not part of the IEC 60601‑1 3rd edition scheme for dental extra-oral X-ray equipment.

All requirements addressing integrated X-ray tube assemblies are covered by this particular standard. Therefore IEC 60601‑2‑28 does not apply to me equipment in the scope of this International Standard with the exception of X-ray tube assemblies that are replaceable in the field.

NOTE 9 Requirements particular to dental x-ray-equipment which were included in previous editions of the collateral standard IEC 60601‑1‑3 or the particular standard IEC 60601‑2‑28 have been extracted and moved into this particular standard.

NOTE 10 For x-ray equipment in the scope of this particular standard X-ray tube assemblies are x-ray monoblock assemblies.

201.1.2 Object

Replacement:

The object of this particular standard is to establish particular basic safety and essential performance requirements for me equipment for extra-oral dental radiography.

201.1.3 Collateral standards

Addition:

This particular standard refers to those applicable collateral standards that are listed in Clause 2 of the general standard and Clause 201.2 of this particular standard.

IEC 60601‑1‑2 and IEC 60601‑1‑3 apply as modified in Clause 202 and 203 respectively. A1_startIEC 60601‑1‑8, IEC 60601‑1‑102), IEC 60601‑1‑113) and IEC 60601‑1‑124) do not apply.A1_end All other published collateral standards in the IEC 60601‑1 series apply as published.

NOTE operators of dental extra-oral X-ray equipment are used to audible signals as required in this particular standard rather than to the concepts of IEC 60601‑1‑8. Therefore IEC 60601‑1‑8 does not apply.

201.1.4 Particular standards

Replacement:

In the IEC 60601 series, particular standards may modify, replace or delete requirements contained in the general standard or collateral standards as appropriate for the particular me equipment under consideration, and may add other basic safety and essential performance requirements.

A requirement of a particular standard takes priority over the general standard.

For brevity, IEC 60601‑1 is referred to in this particular standard as the general standard. Collateral standards are referred to by their document number.

The numbering of clauses and subclauses of this particular standard corresponds to that of the general standard with the prefix “201” (e.g. 201.1 in this standard addresses the content of Clause 1 of the general standard) or applicable collateral standard with the prefix “20x” where x is the final digit(s) of the collateral standard document number (e.g. 202.4 in this particular standard addresses the content of Clause 4 of the 60601-1-2 collateral standard, 203.4 in this particular standard addresses the content of Clause 4 of the 60601-1-3 collateral standard, etc.). The changes to the text of the general standard are specified by the use of the following words:

“Replacement” means that the clause or subclause of the general standard or applicable collateral standard is replaced completely by the text of this particular standard.

“Addition” means that the text of this particular standard is additional to the requirements of the general standard or applicable collateral standard.

“Amendment” means that the clause or subclause of the general standard or applicable collateral standard is amended as indicated by the text of this particular standard.

Subclauses, figures or tables which are additional to those of the general standard are numbered starting from 201.101. However due to the fact that definitions in the general standard are numbered 3.1 through 3.139, additional definitions in this standard are numbered beginning from 201.3.201. Additional annexes are lettered AA, BB, etc., and additional items aa), bb), etc.

Subclauses, figures or tables which are additional to those of a collateral standard are numbered starting from 20x, where “x” is the number of the collateral standard, e.g. 202 for IEC 60601‑1‑2, 203 for IEC 60601‑1‑3, etc.

The term “this standard” is used to make reference to the general standard, any applicable collateral standards and this particular standard taken together.

Where there is no corresponding clause or subclause in this particular standard, the clause or subclause of the general standard or applicable collateral standard, although possibly not relevant, applies without modification; where it is intended that any part of the general standard or applicable collateral standard, although possibly relevant, is not to be applied, a statement to that effect is given in this particular standard.



About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X