Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(317)
(572)
(44)
(234)
(969)
(649)
(2114)
(64)
(92448)
(54)
(535)
(117)
(33)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6217)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • BSI
    BS EN 1993-4-2:2007+A1:2017 Eurocode 3. Design of steel structures - Tanks
    Edition: 2018
    $497.46
    / user per year

Description of BS EN 1993-4-2:2007+A1:2017 2018

  1. Part 4-2 of Eurocode 3 provides principles and application rules for the structural design of vertical cylindrical, conical and pedestal above ground steel tanks for the storage of liquid products with the following characteristics:

    1. tanks with capacity greater than 100 m3 (100 000 l);

    2. tanks that have significant fabrication or assembly on site;

    3. shop-fabricated tanks with conical bottoms, supported on skirts or columns;

    4. tanks with characteristic internal pressures above the liquid surface not more negative than –0,1 bar and not greater than 0,5 bar1);5)

    5. design metal temperatures limited to the ranges:

      1. tanks constructed using structural steel grades, –50°C < T < +300°C;

      2. tanks constructed using austenitic stainless steels, –165°C < T < +300°C;

      3. tanks constructed with special steel grades that have defined yield strengths up to higher temperatures, –165°C < T < the maximum defined temperature for the grade;

      4. tanks susceptible to failure by fatigue, T < 150°C;

    6. in cylindrical ground-supported tanks, the maximum design liquid level not higher than the top of the cylindrical shell.

  2. This Part 4.2 is concerned only with the requirements for resistance and stability of steel tanks. Other design requirements are covered by EN 14015 for ambient temperature tanks and by EN 14620 for cryogenic tanks, and by EN 1090 for fabrication and erection considerations. These other requirements include foundations and settlement, fabrication, erection and testing, functional performance, and details like man-holes, flanges, and filling devices.

  3. Provisions concerning the special requirements of seismic design are provided in EN 1998-4 (Eurocode 8 Part 4 “Design of structures for earthquake resistance: Silos, tanks and pipelines”), which complements the provisions of Eurocode 3 specifically for this purpose.

  4. The design of a supporting structure for a tank is dealt with in EN 1993-1-1.

  5. The design of an aluminium roof structure on a steel tank is dealt with in EN 1999-1-5.

  6. Foundations in reinforced concrete for steel tanks are dealt with in EN 1992 and EN 1997.

  7. Numerical values of the specific actions on steel tanks to be taken into account in the design are given in EN 1991-4 “Actions on Silos and Tanks”. Additional provisions for tank actions are given in annex A to this Part 4.2 of Eurocode 3.

  8. This Part 4-2 does not cover:

    • tanks of rectangular planform;

    • tanks with capacity below 100 m3;

    • tanks exposed to fire (refer to EN 1993-1-2);

    • tanks with dished ends and diameter less than 5 m;

    • cylindrical tanks with an aspect ratio of height to diameter greater than 3.

  9. The circular planform tanks covered by this standard are restricted to axisymmetric structures, though they can be subject to unsymmetrical actions, and can be unsymmetrically supported.