Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(573)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(541)
(117)
(33)
(21)
(20)
(93277)
(3)
(17)
(1)
(351)
(300)
(6217)
(240)
(16)
(5)
(1635)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS 1894:1992 Specification for design and manufacture of electric boilers of welded construction
    Edition: 1992
    $538.63
    / user per year

Description of BS 1894:1992 1992

1.1.1 This British Standard specifies requirements for the design and manufacture, including materials, workmanship, inspection, testing, documentation and marking, of boilers utilizing electrical energy by the use of electrodes or immersion elements. The boilers dealt with are of cylindrical design, either horizontal or vertical, constructed from carbon or carbon manganese steels by fusion welding for which the limits of application are given in table 1.1.1.

Table 1.1.1. Limits of application
Classification Limit
Class I Steam and hot water boilers which exceed the limitations specified for class II and class III boilers
Class II Steam and hot water boilers the design pressure of which does not exceed 1.14 N/mm2 and the design pressure of which (in N/mm2), multiplied by the internal diameter in millimetres, does not exceed 1450
Class III

Steam boilers the design pressure of which does not exceed 0.23 N/mm2

Unvented hot water boilers the design pressure of which does not exceed 0.45 N/mm2

Vented hot water boilers the design pressure of which does not exceed 0.77 N/mm2

The standard applies to electric boilers which provide hot water, steam or superheated steam for use in industrial and commercial applications.

NOTE. Notwithstanding the materials quoted above this does not preclude the use of other materials, such as stainless steels or copper, copper linings, etc. (see 2.1) where the boiler otherwise falls within the limits of this specification, taking the allowable stresses from another appropriate specification.

1.1.2 In addition to the definitive requirements, this standard also requires the items detailed in 1.6 to be documented. For compliance with this standard, both the definitive requirements and the documented items have to be satisfied.



Includes materials, workmanship, inspection, testing, documentation and marking of boilers utilizing electrodes or immersion elements to provide hot water, steam or superheated steam. The boilers are of cylindrical design, constructed from carbon or carbon manganese steels by fusion welding.