ASTM E1251-94(1999)
Historical Standard: ASTM E1251-94(1999) Standard Test Method for Optical Emission Spectrometric Analysis of Aluminum and Aluminum Alloys by the Argon Atmosphere, Point-to-Plane, Unipolar Self-Initiating Capacitor Discharge
SUPERSEDED (see Active link, below)
ASTM E1251
1. Scope
1.1 This test method provides for the optical emission spectrometric analysis of aluminum and aluminum alloys, in cast or wrought form, for the following elements in the concentration ranges indicated:
Element Concentration, Range, % Silicon 0.001 to 24.0 Copper 0.001 to 20.0 Magnesium 0.001 to 11.0 Zinc 0.001 to 10.0 Tin 0.001 to 7.5 Nickel 0.001 to 4.0 Iron 0.001 to 3.5 Lithium 0.005 to 3.0 Manganese 0.001 to 2.0 Cobalt 0.001 to 2.0 Silver 0.001 to 1.5 Chromium 0.001 to 1.0 Zirconium 0.001 to 1.0 Lead 0.002 to 0.7 Bismuth 0.001 to 0.7 Cadmium 0.001 to 0.5 Beryllium 0.0001 to 0.5 Titanium 0.001 to 0.5 Antimony 0.001 to 0.5 Vanadium 0.001 to 0.15 Strontium 0.0001 to 0.07 Gallium 0.001 to 0.05 Sodium 0.0001 to 0.05 Boron 0.0001 to 0.05 Barium 0.0001 to 0.05 Calcium 0.001 to 0.05 Phosphorus 0.0001 to 0.011.2 This test method is suitable primarily for the control analysis of chill-cast specimens. Other forms may be analyzed, provided that (1) they are sufficiently massive to prevent undue heating, (2) they permit machining flat surfaces having a minimum diameter of approximately 15 mm, and (3) reference materials of similar metallurgical condition and chemical composition are available.
1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific safety hazard statements are given in 8.2 and Section 10.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
E135 Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials
E158 Practice for Fundamental Calculations to Convert Intensities into Concentrations in Optical Emission Spectrochemical Analysis
E172 Practice for Describing and Specifying the Excitation Source in Emission Spectrochemical Analysis
E305 Practice for Establishing and Controlling Atomic Emission Spectrochemical Analytical Curves
E406 Practice for Using Controlled Atmospheres in Spectrochemical Analysis
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
E716 Practices for Sampling and Sample Preparation of Aluminum and Aluminum Alloys for Determination of Chemical Composition by Spectrochemical Analysis
E826 Practice for Testing Homogeneity of a Metal Lot or Batch in Solid Form by Spark Atomic Emission Spectrometry
E876 Practice for Use of Statistics in the Evaluation of Spectrometric Data
E1329 Practice for Verification and Use of Control Charts in Spectrochemical Analysis
E1507 Guide for Describing and Specifying the Spectrometer of an Optical Emission Direct-Reading Instrument
Keywords
aluminum; aluminum alloys; Spark Atomic Emission Spectrometry (Spark-AES); Aluminum alloys--spectrochemical analysis; Aluminum (spectrochemical analysis); Argon atmospheres; Calibration--spectrochemical analysis instrumentation; Capacitor discharge; Excitation; Gas flow; Optical emission spectrometry (OES); Point-to-point technique; Unipolar self-initiating capacitor discharge;
ICS Code
ICS Number Code 77.120.10 (Aluminium and aluminium alloys)
DOI: 10.1520/E1251-94R99
ASTM International is a member of CrossRef.