Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(572)
(44)
(234)
(969)
(652)
(2114)
(64)
(92448)
(54)
(535)
(117)
(33)
(20)
(19)
(93277)
(3)
(17)
(1)
(351)
(300)
(6217)
(239)
(16)
(5)
(1621)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • ASTM
    E1192-23 Standard Guide for Conducting Acute Toxicity Tests on Aqueous Ambient Samples and Effluents with Fishes, Macroinvertebrates, and Amphibians
    Edition: 2023
    $86.11
    Unlimited Users per year

Description of ASTM-E1192 2023

ASTM E1192-23

Active Standard: Standard Guide for Conducting Acute Toxicity Tests on Aqueous Ambient Samples and Effluents with Fishes, Macroinvertebrates, and Amphibians




ASTM E1192

Scope

1.1 This guide covers procedures for obtaining laboratory data concerning the adverse effects of an aqueous effluent on certain species of freshwater and saltwater fishes, macroinvertebrates, and amphibians, usually during 2 day to 4 day exposures, depending on the species, using the static, renewal, and flow-through techniques. These procedures will probably be useful for conducting acute toxicity tests on aqueous effluents with many other aquatic species, although modifications might be necessary.

1.2 Other modifications of these procedures might be justified by special needs or circumstances. Although using appropriate procedures is more important than following prescribed procedures, results of tests conducted using unusual procedures are not likely to be comparable to results of many other tests. Comparison of results obtained using modified and unmodified versions of these procedures might provide useful information concerning new concepts and procedures for conducting acute toxicity tests on aqueous effluents.

1.3 This guide is based in large part on Guide E729 where addition details are provided for test elements that may be applicable to the ambient and effluent toxicity testing described in this method. The major differences between the two guides are (1) the maximum test concentration is 100 % effluent or ambient sample, (2) testing is not chemical-specific, and (3) the holding time of effluent and ambient samples is often considerably less than that for chemicals and other test materials. Because the sample is often a complex mixture of chemicals, analytical tests cannot generally be used to confirm exposure concentrations.

1.4 Selection of the technique to be used in a specific situation will depend upon the needs of the investigator and upon available resources. Static tests provide the most easily obtained measure of acute toxicity but should not last longer than 48 h. Renewal and flow-through tests may last longer than 48 h because the pH and concentrations of dissolved oxygen and effluent are maintained at desired levels and degradation and metabolic products are removed. Static tests might not be applicable to effluents that have a high oxygen demand or contain materials that (1) are highly volatile, (2) are rapidly biologically or chemically transformed in aqueous solutions, or (3) are removed from test solutions in substantial quantities by the test chambers or organisms during the test. Flow-through tests are generally preferable to renewal tests, although in some situations a renewal test might be more cost-effective than a flow-through test.

1.5 In the development of these procedures, an attempt was made to balance scientific and practical considerations and to ensure that the results will be sufficiently accurate and precise for the applications for which they are commonly used. A major consideration was that the common uses of the results of acute tests on effluents do not require or justify stricter requirements than those set forth in this guide. Although the tests may be improved by using more organisms, longer acclimation times, and so forth, the requirements presented in this guide should usually be sufficient.

1.6 Results of acute toxicity tests should usually be reported in terms of a median lethal concentration (LC50) or median effective concentration (EC50). In some situations, it might be necessary only to determine whether a specific concentration is acutely toxic to the test species or whether the LC50 or EC50 is above or below a specific concentration.

1.7 This guide is arranged as follows:

 

Section

 

 

Referenced Documents

  2

Terminology

  3

Summary of Guide

  4

Significance and Use

  5

Hazards

  7

Apparatus

  6

 Facilities

  6.1

 Special Requirements

  6.2

 Construction Materials

  6.3

 Metering System

  6.4

 Test Chambers

  6.5

 Cleaning

  6.6

 Acceptability

  6.7

Dilution Water

  8

 Requirements

  8.1

 Source

  8.2

 Treatment

  8.3

 Characterization

  8.4

Effluent

  9

 Sampling Point

  9.1

 Collection

  9.2

 Preservation

  9.3

 Treatment

  9.4

 Test Concentration(s)

  9.5

Test Organisms

  10

 Species

  10.1

 Age

  10.2

 Source

  10.3

 Care and Handling

  10.4

 Feeding

  10.5

 Disease Treatment

  10.6

 Holding

  10.7

 Acclimation

  10.8

 Quality

  10.9

Procedure

  11

 Experimental Design

  11.1

 Dissolved Oxygen

  11.2

 Temperature

  11.3

 Loading

  11.4

 Beginning the Test

  11.5

 Feeding

  11.6

 Duration of Test

  11.7

 Biological Data

  11.8

 Other Measurements

  11.9

Analytical Methodology

  12

Acceptability of Test

  13

Calculation or Results

  14

Report

  15

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7.

1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


Keywords

acute toxicity; ambient samples; amphibians; EC50; effluents; freshwater fishes; freshwater invertebrates; LC50; saltwater fishes; saltwater invertebrates ;


ICS Code

ICS Number Code 13.060.70 (Examination of water for biological properties)


DOI: 10.1520/E1192-23

The following editions for this book are also available...

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $883.58 Buy
VAR
ASTM
[+] $5,933.17 Buy
VAR
ASTM
[+] $1,056.87 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X