FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Technical Bulletin
All
|
Description of ASTM-D6442 2012ASTM D6442 - 06(2012)Standard Test Method for Determination of Copper Release Rate From Antifouling Coatings in Substitute Ocean WaterActive Standard ASTM D6442 | Developed by Subcommittee: D01.45 Book of Standards Volume: 06.02 ASTM D6442Significance and Use 4.1 This test method is designed to provide a laboratory procedure to quantify and characterize the release rates of copper from antifouling coatings in substitute ocean water over a period of immersion under specified laboratory conditions of constant temperature, pH, salinity, and low copper concentration. Quantitative measurement of the release rate is necessary to help in selection of materials, in providing quality control, and in understanding the performance mechanism. 4.2 Results from this test method establish a pattern of copper release from an antifouling coating over a minimum of 45 days exposure under controlled laboratory conditions. Copper release rates from antifouling paints in-service vary over the life of the coating system depending on the formulation and on the physical and chemical properties of the environment. Factors such as differences in berthing locations, operating schedules, length of service, condition of paint film surface, temperature, pH, and salinity influence the actual release rate under environmental conditions. Results obtained using this test method do not reflect actual copper release rates that will occur in-service, but provide comparisons of the release rate of different antifouling formulations in substitute ocean water under the prescribed laboratory conditions. 4.3 By comparison with copper release rate measurements obtained either by direct measurements of copper release rate from AF coating systems on ship hulls, or copper release rate measurements from AF coating systems from harbor exposed panels, all available data indicate that the results of this test method (Test Method D6442) significantly overestimate the release rate of copper when compared to release rates under in-service conditions. Published results demonstrate that this test method produces higher measurements of copper release rate than from direct in-situ measurements for the same coating on in-service ship hulls and harbor-exposed panels. The difference between the results of this test method and the panel and ship studies was up to a factor of about 30 based on data for several commercial antifouling coatings. 3 , 4 Realistic estimates of the copper release from a ship's hull under in-service conditions can only be obtained from this test method where the difference between the results obtained by this test method and the release rate from an AF coating in-service is taken into account. 4.4 Where the results of this test method are used in the process of generating environmental risk assessments, for environmental loading estimates, or for regulatory purposes, it is most strongly recommended that the relationship between laboratory release rates and actual environment inputs is taken into account to allow a more accurate approximation of the copper release rate from antifouling coatings under real-life conditions. This can be accomplished through the application of appropriate correction factors. 4 1. Scope 1.1 This test method covers the laboratory determination of the rate at which copper is released from an antifouling (AF) coating in substitute ocean water. The practical limits for quantifying copper release rates by this method are from 1.8 to 500 ?g cm -2 d -1 . This range may be extended to 0.2 to 500 ?g cm -2 d -1 if the analytical procedure described in Appendix X1 is followed.
Note 1 The term substitute ocean water is used throughout this standard to refer to artificial or synthetic
seawater prepared in accordance with Practice D1141 .
1.2 The procedure contains the preparation steps for the release rate determination of copper from antifouling paints including apparatus, reagents, holding tank conditions, and sampling point details. Analysis for the concentration of copper in substitute ocean water requires the accurate determination of copper at the low parts ?g L -1 (parts per billion, ppb) level. To detect and correct for reagent impurities, acceptable analytical precision standards are necessary. Therefore, the limit of quantitation (LOQ) for copper in substitute ocean water for the analytical method shall be 10 ?g L -1 (10 ppb) or less. The procedure for determining the LOQ for copper in substitute ocean water for the analytical method is found in Annex A2 . 1.3 A suitable method is described in Appendix X1 (graphite furnace atomic absorption spectroscopy, GF-AAS). Other analytical methods may be utilized with relevant procedural changes, as needed, to accommodate selected specific methods. Such methods must meet the limit of quantitation for copper in substitute ocean water of 10 ?g L -1 (10 ppb) or less. See 1.2 . 1.4 This results of this test method do not reflect environmental copper release rates for antifouling products, and are not suitable for direct use in the process of generating environmental risk assessments, environmental loading estimates, or for establishing release rate limits for regulatory purposes. See also Section 4 on Significance and Use. 1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety practices and to determine the applicability of regulatory limits prior to use. For specific hazard statements, see Section 7 .
ASTM Standards D1005 Test Method for Measurement of Dry-Film Thickness of Organic Coatings Using Micrometers D1141 Practice for the Preparation of Substitute Ocean Water D1193 Specification for Reagent Water Keywords antifouling coating; copper; release rate; ICS Code ICS Number Code 87.040 (Paints and varnishes) DOI: 10.1520/D6442-06R12 ASTM International is a member of CrossRef. ASTM D6442This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |