FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Technical Bulletin
All
|
Description of ASTM-D3739 2010ASTM D3739 - 06(2010)Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse OsmosisActive Standard ASTM D3739 | Developed by Subcommittee: D19.08 Book of Standards Volume: 11.02 ASTM D3739Significance and Use In the design and operation of reverse osmosis installations, it is important to predict the calcium carbonate scaling properties of the concentrate stream. Because of the increase in total dissolved solids in the concentrate stream and the difference in passages for calcium ion, bicarbonate ion, and free CO 2 , the calcium carbonate scaling properties of the concentrate stream will generally be quite different from those of the feed solution. This practice permits the calculation of the Langelier Saturation Index for the concentrate stream from the feed water analyses and the reverse osmosis operating parameters. A positive Langelier Saturation Index indicates the tendency to form a calcium carbonate scale, which can be damaging to reverse osmosis performance. This practice gives various procedures for the adjustment of the Langelier saturation index. The tendency to form CaCo 3 scale can be suppressed by the addition of antiscalents or crystal modifiers. Suppliers of antisealents and crystal modifiers can provide information on the scale inhibition peformance of these types of chemical. Their use may be appropriate for reducing scale formation in RO systems. The RO system supplier should be consulted prior to the use of antisealents and crystal modifiers to ensure they will not have a negative impact on the RO system. 1. Scope 1.1 This practice covers the calculation and adjustment of the Langelier saturation index for the concentrate stream of a reverse osmosis device. This index is used to determine the need for calcium carbonate scale control in the operation and design of reverse osmosis installations. This practice is applicable for concentrate streams containing xx 10 to 10 000 mg/L of total dissolved solids. For concentrate containing over 10 000 mg/L see Practice D4582 . 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards D511 Test Methods for Calcium and Magnesium In Water D1067 Test Methods for Acidity or Alkalinity of Water D1129 Terminology Relating to Water D1293 Test Methods for pH of Water D1888 Methods Of Test for Particulate and Dissolved Matter in Water D4194 Test Methods for Operating Characteristics of Reverse Osmosis and Nanofiltration Devices D4195 Guide for Water Analysis for Reverse Osmosis and Nanofiltration Application D4582 Practice for Calculation and Adjustment of the Stiff and Davis Stability Index for Reverse Osmosis D6161 Terminology Used for Microfiltration, Ultrafiltration, Nanofiltration and Reverse Osmosis Membrane Processes Keywords CaCO 3 scale; Langelier Saturationndex; LSI; reverse osmosis; scaling; Calcium carbonate (CaCO 3 ) scaling properties; Desalinating (reverse osmosis) devices; Langelier saturation index; Reverse osmosis (RO) installations; Water analysis ; ICS Code ICS Number Code 07.030 (Physics. Chemistry) DOI: 10.1520/D3739-06R10 ASTM International is a member of CrossRef. ASTM D3739This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |