Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(325)
(572)
(44)
(234)
(969)
(649)
(2114)
(64)
(92448)
(54)
(535)
(117)
(33)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6217)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • ASTM
    C688-08 Standard Specification for Functional Additions for Use in Hydraulic Cements
    Edition: 2008
    $93.60
    Unlimited Users per year

Description of ASTM-C688 2008

ASTM C688-08

Historical Standard: Standard Specification for Functional Additions for Use in Hydraulic Cements




ASTM C688

Scope

1.1 This specification covers methods to investigate the effectiveness of a material to beneficially change the properties of hydraulic cements when the material is incorporated during manufacture of the cement.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 The effect of additions in cement may markedly change properties other than those they are intended to modify. This specification is designed to test for such changes. Table 1 sets forth values for those properties of cement pastes and mortars that would permit a judgment of the changes effected by an addition. Likewise, Table 2 sets forth similar criteria for concrete. Certain additions may be found effective for more than one purpose as indicated in 3.1.4 and 3.1.5.

TABLE 1 Criteria for Evaluating Neat Cement and Mortar Containing Functional Cement Additions

Tests Type of Addition
Water Reducing Retarding Accelerating Water-Reducing
and Retarding
Water-Reducing and
Accelerating
Set-Control
Normal consistency, deviation from control,
percentage pointsA
−1.0 min +1.0 max +1.0 max −1.0 min −1.0 mm ±1.0 max
Standard consistency (flow) deviation from
control, percentage pointsA
−4.0 min +2.0 max +2.0 max −4.0 min −4.0 min ±2.0 max
Setting time, (Gillmore) deviation from control,
h:min
Initial
At least ... 1:00 laterB 1:00 laterB ...
Not more than 1:00 earlier 3:30 later 1:30 earlier 3:30 later 1:30 earlier 1:00 earlier
nor nor nor nor
1:30 later 1:30 later 1:30 later 1:30 later
Setting time, Vicat InitialC
At least ... 0:50 laterB ... ... ...
Not more than 0:50 earlier 2:50 later 1:15 earlier 0:50 laterB 1:15 earlier 0:50 earlier
nor nor nor nor
1:15 later 1:15 later 2:50 later 1:15 later 1:15 later
Final
Not more than 1:00 earlier 3:30 later 1:00 earlier 3:30 later 1:00 earlier 1:00 earlier
nor nor nor nor
1:30 later 1:30 later 1:30 later 1:30 later
Compressive strength, min, percent of control:D
1 day in moist air 110 90 125E 90 125 F
1 day in moist air, 2 days in water 110 90 125E 100 125
1 day in moist air, 6 days in water 110 90 100 110 110
1 day in moist air, 27 days in water 110 95 95 110 110
Autoclave Expansion
max increase in % change in length compared to control

0.10

0.10

0.10

0.10

0.10

0.10
Drying Shrinkage of Mortar
max % change in length compared to control

0.020

0.020

0.030

0.020

0.020

0.020

A The minus sign indicates that the percentage of water required shall be less than that of the control cement by at least the indicated percentage points.

B Or 50 % later, whichever is the lesser.

C Either Vicat or the Gillmore time of setting method shall be used at the choice of the manufacturer.

D The compressive strength of mortar containing the test cement shall be not less than 95 % of that attained at any previous test age. The objective of this limit is to require that the strength of mortar containing the addition under test shall not decrease with age.

E In cases where the accelerated set time only is required, the strength can be reduced to 100 % of the control.

F The grand average of the 1, 3, 7, and 28-day strengths shall be not less than 95 % of the grand average for the corresponding control cement.

TABLE 2 Criteria for Evaluating Concrete Containing Functional Cement AdditionsA

Tests Type of Addition
Water Reducing Retarding Accelerating Water-Reducing
and Retarding
Water-Reducing
and Accelerating
Water content, max, percent of control 95 ... ... 95 95
Time of setting, (penetration) deviation from
control, h:min:
Initial
At least ... 1:00 laterB 1:00 laterB
Not more than 1:00 earlier 3:30 later 3:30 earlier 3:30 later 3:30 earlier
nor
Final 1:00 later
Not more than 1:00 earlier 3:30 later ... 3:30 later ...
nor
1:30 later
Compressive strength, min, percent of
control:C
1 dayD 110 85 125E 100 125
3 days 110 85 125E 100 125
7 days 110 90 100 110 110
28 days 110 90 95 110 110
3 months 100 90 95 100 100
1 year 100 90 95 100 100
Flexural strength, min, percent of
control:C
1 dayD 100 85 110 90 110
3 days 100 85 110 100 110
7 days 100 90 100 100 100
28 days 100 90 90 100 100
3 months 100 90 90 100 100
1 year 100 90 90 100 100
Bond strength, percent of control:
28 days 100 90 100 100 100
Volume change, expressed as change in
length, max, increase over control,
percentage points:
28 days 0.010 0.010 0.030 0.010 0.010
3 months 0.010 0.010 0.030 0.010 0.010
1 year 0.010 0.010 0.030 0.010 0.010
Durability factor, min, percent of controlF 80 80 80 80 80

A The values in the table are intended to allow for normal variation in test results. For example, the object of the 90 % compressive strength requirement for a retarding addition is to require a level of performance comparable to that of the reference concrete.

B Or 50 % later, whichever is the lesser.

C The compressive and flexural strength of the concrete containing the addition under test at any test age shall be not less than 90 % of that attained at any previous test age. The objective of this limit is to require that the compressive or flexural strength of the concrete containing the addition under test shall not decrease with age.

D One-day strengths applicable only to Type III cement. One-year strength tests shall be made; however, the addition may be approved after completion of the 3-month strength results, at the discretion of the purchaser.

E In cases where the accelerated set time only is required, the strength can be reduced to 100 % of the control.

F This requirement is applicable only when the addition is to be used in air-entrained concrete.


Keywords

additions; functional; hydraulic cement; Additives--cement/concrete; Cement materials/applications--specifications; Hydraulic cement concrete--specifications


ICS Code

ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)


DOI: 10.1520/C0688-08

The following editions for this book are also available...

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $849.32 Buy
VAR
ASTM
[+] $5,812.65 Buy
VAR
ASTM
[+] $10,801.41 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X