Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(326)
(573)
(44)
(234)
(982)
(652)
(2114)
(64)
(92448)
(54)
(547)
(124)
(33)
(21)
(20)
(93277)
(3)
(17)
(1)
(351)
(306)
(6217)
(240)
(16)
(5)
(1635)
(16)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ASTM
    C1590-04(2009) Standard Practice for Alternate Actinide Calibration for Inductively Coupled Plasma-Mass Spectrometry
    Edition: 2009
    $93.60
    Unlimited Users per year

Description of ASTM-C1590 2009

ASTM C1590 - 04(2009)

Standard Practice for Alternate Actinide Calibration for Inductively Coupled Plasma-Mass Spectrometry

Active Standard ASTM C1590 | Developed by Subcommittee: C26.05

Book of Standards Volume: 12.01




ASTM C1590

Significance and Use

One of the benefits of this standard practice is the ability to calibrate for the analysis of highly radioactive actinides using calibration standards at much lower specific activities (that is, 232 Th and 238 U). Environmental laboratories may find this standard practice useful if facilities are not available to handle the highly radioactive standards of the individual actinides of interest.

The degree of actual mass bias is variable and is dependent upon instrument tune parameters. This standard practice uses universal interference equations to derive a mass bias correction that is specific to the instrument parameters and tune used for sample data acquisition and not based on a historical average.

Mass bias correction uses the instrument software interference equations and does not require additional subsequent off-line calculations.

The methodology that this standard practice is based on has been used for the determination of 232 Th and 237 Np in enriched uranium solutions and the determination of 241 Am in plutonium and uranium legacy oxides following dissolution and ion extraction chromatography separation.

1. Scope

1.1 This practice provides guidance for an alternate linear calibration for the determination of selected actinide isotopes in appropriately prepared aqueous solutions by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). This alternate calibration is mass bias adjusted using thorium-232 ( 232 Th) and uranium-238 ( 238 U) standards. One of the benefits of this standard practice is the ability to calibrate for the analysis of highly radioactive actinides using calibration standards at much lower specific activities. Environmental laboratories may find this standard practice useful if facilities are not available to handle the highly radioactive standards of the individual actinides of interest.

1.2 The instrument response for a series of determinations of known concentration of 232 Th and 238 U defines the mass versus response relationship. For each standard concentration, the slope of the line defined by 232 Th and 238 U is used to derive linear calibration curves for each mass of interest using interference equations. The mass bias corrected calibration curves, although generated from interference equations, are specific to the instrument operating parameters and tuning in effect at the time of data acquisition. Because interference equations are part of the normal ICP-MS manufacturer's software package, this calibration methodology is widely applicable.

1.3 For this standard practice, the actinide atomic mass range that has been studied is from amu 232 244. Guidance for an extended range of amu 228 248 is given in this practice.

1.4 Using this practice, analyte concentrations are reported at each amu and not by element total (that is, 239 Pu versus plutonium).

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

C859 Terminology Relating to Nuclear Materials

C1168 Practice for Preparation and Dissolution of Plutonium Materials for Analysis

C1347 Practice for Preparation and Dissolution of Uranium Materials for Analysis

C1411 Practice for The Ion Exchange Separation of Uranium and Plutonium Prior to Isotopic Analysis

C1414 Practice for The Separation of Americium from Plutonium by Ion Exchange

C1463 Practices for Dissolving Glass Containing Radioactive and Mixed Waste for Chemical and Radiochemical Analysis

D1193 Specification for Reagent Water


Keywords

actinides; inductively coupled plasma-mass spectrometry (ICP-MS); mass bias; thorium; uranium; Actinides; ICP-MS (inductively-coupled plasma-mass spectrometry); Thorium; Uranium ;


ICS Code

ICS Number Code 71.040.50 (Physicochemical methods of analysis)


DOI: 10.1520/C1590-04R09

ASTM International is a member of CrossRef.

ASTM C1590

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $1,152.58 Buy
VAR
ASTM
[+] $1,737.94 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X