ASME CSD-1 - 2021 Controls and Safety Devices for Automatically Fired Boilers, 2021
- CONTENTS
- FOREWORD
- ASME CSDAFB COMMITTEE ROSTER
- CORRESPONDENCE WITH THE CSDAFB COMMITTEE
- ASME CSD-1–2021 SUMMARY OF CHANGES
- Part CG General [Go to Page]
- CG-100 GENERAL REQUIREMENTS [Go to Page]
- CG-110 Scope
- CG-120 Service Limitations
- CG-130 Exclusions
- CG-140 Acceptance of Other Listings
- CG-150 Jurisdictional Adoption of ASME CSD-1
- CG-160 Metric (SI) Units
- CG-200 GENERAL PROVISIONS [Go to Page]
- CG-210 General
- CG-220 Installation
- CG-230 Observation Ports
- CG-240 Guarding
- CG-250 Annunciator Systems
- CG-260 Combustion Air
- CG-300 MATERIAL REQUIREMENTS [Go to Page]
- CG-310 Components
- CG-400 TESTING AND MAINTENANCE [Go to Page]
- CG-410 Cleaning
- CG-420 Testing
- CG-430 Maintenance
- CG-440 Operational Testing
- CG-500 CERTIFICATION AND REPORTING [Go to Page]
- CG-510 Certification and Reporting
- CG-600 OPERATION [Go to Page]
- CG-610 Lockout
- CG-700 DEFINITIONS
- Part CM Testing and Maintenance [Go to Page]
- CM-100 PERIODIC TESTING AND MAINTENANCE [Go to Page]
- CM-110 General
- CM-120 Familiarity With Equipment and Procedures
- CM-130 Periodic Maintenance and Testing
- Part CE Electrical [Go to Page]
- CE-100 ELECTRICAL REQUIREMENTS [Go to Page]
- CE-110 General
- CE-120 Overcurrent Protection
- CE-130 Motors
- CE-140 Ignition System
- CE-150 Wiring
- CE-160 Bonding and Grounding
- CE-170 Annunciation, Status, and Control Wiring to Primary Safety Control Systems
- Part CW Steam and Waterside Control [Go to Page]
- CW-100 AUTOMATIC LOW-WATER FUEL CUTOFF AND/OR COMBINED WATER FEEDING DEVICE [Go to Page]
- CW-110 General Requirements for Water Level Controls for All Boilers
- CW-120 Requirements for Water Level Controls for Low-Pressure Steam Boilers
- CW-130 Requirements for Water Level Controls for Hot Water Heating Boilers
- CW-140 Requirements for Water Level Controls for High-Pressure Steam Boilers
- CW-150 Requirements for Operating and Safety Controls for Electrically Heated Boilers
- CW-200 AUTOMATIC FUEL CUTOFF FOR FORCED CIRCULATION BOILERS [Go to Page]
- CW-210 Requirements for Flow or Temperature Sensing Devices for Forced Circulation Boilers
- CW-300 PRESSURE CONTROLS [Go to Page]
- CW-310 Requirements for Pressure Controls for Steam Boilers
- CW-400 TEMPERATURE CONTROLS [Go to Page]
- CW-410 Requirements for Temperature Controls for Hot Water Boilers
- CW-500 SAFETY AND SAFETY RELIEF VALVES [Go to Page]
- CW-510 Requirements for Steam and Hot Water Heating Boilers
- CW-520 Requirements of Hot Water Supply Boilers
- CW-600 MODULAR BOILERS [Go to Page]
- CW-610 Water Level Controls for Modular Steam Heating Boilers
- CW-620 Pressure Controls for Modular Steam Heating Boilers
- CW-630 Water Level Controls for Modular Hot Water Boilers
- CW-640 Temperature Controls for Modular Hot Water Heating Boilers
- CW-700 VACUUM BOILERS [Go to Page]
- CW-710 Requirements for Vacuum Boilers
- Part CF Combustion Side Control [Go to Page]
- CF-100 GAS-FIRED BOILER UNITS, EQUIPMENT [Go to Page]
- CF-110 Burner Assemblies and Boiler Units
- CF-120 Fuel Train
- CF-130 Filters or Strainers
- CF-140 Sediment Traps and Drips
- CF-150 Manually Operated Gas Shutoff Valves
- CF-160 Gas-Pressure Regulators
- CF-170 Control Valves
- CF-180 Safety Shutoff Valves
- CF-190 Vent Lines, Bleed Lines, Gas-Pressure Relief Lines, Vent Valve Lines, and Feedback Lines for Fuel Train Components
- CF-200 GAS-FIRED BOILER UNITS, PURGING [Go to Page]
- CF-210 Preignition Purging
- CF-220 Control
- CF-300 GAS-FIRED BOILER UNITS, SAFETY CONTROLS [Go to Page]
- CF-310 Primary Safety Control
- CF-320 Automatic Ignition Devices
- CF-330 Action on Flame Failure
- CF-400 OIL-FIRED BOILER UNITS, EQUIPMENT [Go to Page]
- CF-410 Burner Assemblies
- CF-420 Fuel Train
- CF-430 Filters or Strainers
- CF-440 Relief Valves
- CF-450 Pressure and Temperature Switches
- CF-460 Safety Shutoff Valves
- CF-470 Oil-Fired Boiler Units, Purging
- CF-480 Combustion Air Proving
- CF-500 OIL-FIRED BOILER UNITS, SAFETY CONTROLS [Go to Page]
- CF-510 Primary Safety Control
- CF-520 Automatic Ignition Devices
- CF-530 Action on Flame Failure
- CF-540 Automatic Stack Dampers
- CF-600 LOW FIRE START, GAS- OR OIL-FIRED BOILER UNITS [Go to Page]
- CF-610 Low Fire Start
- CF-700 COMBINATION GAS- AND OIL-FIRED UNITS [Go to Page]
- CF-710 Burner Assemblies
- CF-800 ELECTRICALLY HEATED BOILERS [Go to Page]
- CF-810 General
- CF-900 COMBUSTION SIDE CONTROLS FOR MODULAR BOILERS [Go to Page]
- CF-910 Gas Modular Boilers
- CF-920 Oil Modular Boilers
- CF-930 Electric Modular Boilers
- CF-1000 Requirements for the Use of Variable Frequency Drives (VFD) [Go to Page]
- CF-1010 VFD Used on Combustion Air Fan
- Figures [Go to Page]
- Figure CG-700-1 Sediment Trap
- Figure B-1 Typical Gas Fuel Train With Pilot Ignition System and Atmospheric Burners [Greater Than 400,000 Btu/hr (117 kW) and Less Than or Equal to 2,500,000 Btu/hr (733 kW)]
- Figure B-2 Typical Gas Fuel Train With Pilot Ignition System [Greater Than 400,000 Btu/hr (117 kW) and Less Than or Equal to 2,500,000 Btu/hr (733 kW)]
- Figure B-3 Typical Gas Fuel Train With Direct Ignition System [Greater Than 400,000 Btu/hr (117 kW) and Less Than or Equal to 2,500,000 Btu/hr (733 kW)]
- Figure B-4 Typical Gas Fuel Train With Pilot Ignition System [Greater Than 2,500,000 Btu/hr (733 kW) and Less Than or Equal to 5,000,000 Btu/hr (1 465 kW)]
- Figure B-5 Typical Gas Fuel Train With Pilot Ignition System [Greater Than 5,000,000 Btu/hr (1 465 kW) and Less Than 12,500,000 Btu/hr (3 663 kW)]
- Figure B-6 Typical Gas Fuel Train With Pilot Ignition System and Negative (Zero Governor) Main Manifold Gas Pressure [Greater Than 400,000 Btu/hr (117 kW) and Less Than 12,500,000 Btu/hr (3 663 kW)]
- Figure B-7 Typical Gas Fuel Train With Direct Ignition System and Negative (Zero Governor) Main Manifold Gas Pressure [Greater Than 400,000 Btu/hr (117 kW) and Less Than 12,500,000 Btu/hr (3 663 kW)]
- Figure B-8 Typical Oil Fuel Train
- Figure B-9 Example for Sizing of Manifolded Lines
- Figure B-10 Typical Gas Fuel Train Safety Shutoff Valve Arrangements for Multiple-Burner Boiler Units Complying With CF-180(b)
- Tables [Go to Page]
- Table CF-110-1 400,000 Btu/hr (117 kW) and Smaller (Gas — Natural Draft)
- Table CF-110-2 400,000 Btu/hr (117 kW) and Smaller (Power Gas Burners, Mechanical Draft Atmospheric Gas Burners, Pulse Combustion Systems), 3 gph (11.4 L/h) [Approximately 400,000 Btu/hr (117 kW)] and Smaller (Oil)
- Table CF-162-1 Safety Controls for Automatically Fired Units: Power Gas Burners, Mechanical Draft Atmospheric Gas Burners, and Pulse Combustion Systems
- Table CF-162-2 Safety Controls for Automatically Fired Units: Atmospheric Gas Burners — Natural Draft
- Table CF-460-1 Safety Controls for Automatically Fired Units: Oil-Fired Burners
- Table B-1 Figure Index
- Table D-1-1 Periodic Testing Recommended Checklist
- NONMANDATORY APPENDICES [Go to Page]
- NONMANDATORY APPENDIX A COMPARISON OF THIS STANDARD AND ANSI Z21.13/CSA 4.9
- NONMANDATORY APPENDIX B TYPICAL FUEL TRAINS
- NONMANDATORY APPENDIX C MANUFACTURER’S/INSTALLING CONTRACTOR’S REPORT FOR ASME CSD-1
- NONMANDATORY APPENDIX D RECOMMENDED PREVENTIVE MAINTENANCE SCHEDULE [Go to Page]
- D-1 INTRODUCTION
- D-2 DAILY
- D-3 WEEKLY
- D-4 MONTHLY
- D-5 SEMIANNUALLY
- D-6 ANNUALLY
- D-7 AS REQUIRED
- NONMANDATORY APPENDIX E REFERENCES
- NONMANDATORY APPENDIX F GUIDANCE FOR THE USE OF U.S. CUSTOMARY AND SI UNITS IN ASME CSD-1 [Go to Page]
- F-1 USE OF UNITS IN EQUATIONS
- F-2 GUIDELINES USED TO DEVELOP SI EQUIVALENTS
- F-3 SOFT CONVERSION FACTORS [Go to Page]