ASTM F1113-87(2005)e1
Historical Standard: ASTM F1113-87(2005)e1 Standard Test Method for Electrochemical Measurement of Diffusible Hydrogen in Steels (Barnacle Electrode)
SUPERSEDED (see Active link, below)
ASTM F1113
1. Scope
1.1 This test method covers the procedure for measuring diffusible hydrogen in steels by an electrochemical method.
1.2 This test method is limited to carbon or alloy steels, excluding austenitic stainless steels.
1.3 This test method is limited to flat specimens to which the cell can be attached (see 4.6 and 4.8).
1.4 This test method describes testing on bare or plated steel after the plate has been removed (see 4.4).
1.5 This test method is limited to measurements at room temperature, 20 to 25C (68 to 77F).
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
B183 Practice for Preparation of Low-Carbon Steel for Electroplating
B242 Guide for Preparation of High-Carbon Steel for Electroplating
B766 Specification for Electrodeposited Coatings of Cadmium
D1193 Specification for Reagent Water
F519 Test Method for Mechanical Hydrogen Embrittlement Evaluation of Plating/Coating Processes and Service Environments
G3 Practice for Conventions Applicable to Electrochemical Measurements in Corrosion Testing
Keywords
barnacle cell; current transients; diffusion; electrochemical; electrodes; high strength steels; hydrogen contact; hydrogen embrittlement; mobile hydrogen ;
ICS Code
ICS Number Code 25.220.20 (Surface treatment)
DOI: 10.1520/F1113-87R05E01
ASTM International is a member of CrossRef.