Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
Douglas County, 2012 Code Amendments Effective Oct. 1, 2012, 0
- TABLE OF CONTENTS
- Exhibit A
- Exhibit B
- ï‚· Wildfire Mitigation Standards 27
- (Adopted by the Douglas County Board of County Commissioners on 11/04/08)
- Exhibit C
- ï‚· Standard for Water Supplies for Rural Firefighting 45
- (Adopted by the Douglas County Board of County Commissioners on 10/25/95)
- Exhibit D
- ï‚· Installation Standard IS-22-98 - Installation standards for potable water 54
- storage tanks and cisterns for domestic use
- (Adopted by the Douglas County Board of County Commissioners on 09/28/05)
- Exhibit E
- ï‚· Natural Landform Protection Area (NLPA) 57
- AMENDMENTS COMMON TO ALL ADOPTED 2012 INTERNATIONAL CODES
- 20.5 Probationary registration
- The Building Official may issue a probationary registration where the Building Official determines that qualifications must be established prior to issuance of a regular registration.
- 20.6 Expiration of registration and regulations
- All registrations shall expire one (1) year from the date of issuance. Registrations with State issue licenses shall expire thirty (30) days after the State license expires, unless otherwise provided. No permits may be obtained, nor may work already under permit be continued, until the registration has been renewed. Applicants for registration renewals shall meet all current requirements for a new registration.
- 20.7 Insurance requirements
- Prior to registration, the contractor shall file with the Building Official a Certificate of Liability insurance and Worker’s Compensation insurance. The insurance certificate must be signed by an agent of an insurance company stating that the policy, or policies, required by this Section have been issued to the contractor. The policy, or policies, shall state the name of the company, effective date of such polices, and the expiration date of policy or policies. Each policy of insurance shall contain an endorsement to the effect that the insurance carrier shall notify the Douglas County Building Division of the effective date of a reduction or cancellation of the policy. The cancellation or reduction of insurance below the required amount of coverage shall be cause for automatic suspension of the contractor’s registration until coverage is reinstated. All policies shall be kept in effect for the period of the registration. [Go to Page]
- Single occurrence liability insurance shall have the following minimum coverage amount:
- AMENDMENTS TO THE 2012 INTERNATIONAL BUILDING CODE (IBC)
- Exhibit B [Go to Page]
- General [Go to Page]
- Chapter 1 Introduction
- Table 2-3.2 Fuel Hazard Rating [Go to Page]
- Type
- Rating
- Table 2-3.3 Slope Hazard Rating [Go to Page]
- Slope
- Rating
- Table 2-3.4 Structure Hazard Rating [Go to Page]
- Design Characteristics
- Table 2-3.5 Additional Factor Rating [Go to Page]
- Additional Factor
- Chapter 3 Fuel Modification Planning
- Chapter 4 Roads, Streets, and Ways
- Chapter 6 Emergency Water Supplies
- Chapter 7 Structural Design and Construction
- Chapter 8 Public Fire Prevention and Fire safety Information and Education
- Chapter 9 Referenced Publications [Go to Page]
- Section 2 Rural Water Supply Standard for One and Two-Family Dwellings
- APPENDIX “A” [Go to Page]
- A-2-1 General
- A-2-2 Cistern Design.
- A-2-4 Water Supply Access.
- APPENDIX “B”
- INSTALLATION STANDARDS FOR POTABLE WATER STORAGE TANKS AND CISTERNS FOR DOMESTIC USE IS - 22 – 98
- add to Exhibit D Restricted_Parcels_List_edited for 09 adoption.pdf [Go to Page]
- Restricted_Parcels_withinGeoHaz [Go to Page]