Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
International Energy Conservation Code, 1998
- 1998 INTERNATIONAL ENERGY CONSERVATION CODE
- 1998 INTERNATIONAL ENERGY CONSERVATION CODE TITLE PAGE
- COPYRIGHT
- PREFACE
- SAMPLE ORDINANCE FOR ADOPTION OF THE INTERNATIONAL ENERGY CONSERVATION CODE
- TABLE OF CONTENTS
- CHAPTER 1: ADMINISTRATION AND ENFORCEMENT [Go to Page]
- SECTION 101 SCOPE AND GENERAL REQUIREMENTS [Go to Page]
- TABLE 101.4.2.4 PRESCRIPTIVE ENVELOPE COMPONENT CRITERIA ADDITIONS TO AND REPLACEMENT WINDOWS FOR EXISTING SINGLE-FAMILY RESIDENTIAL BUILDINGS
- SECTION 102 MATERIALS AND EQUIPMENT [Go to Page]
- TABLE 102.3(1) U-VALUE DEFAULT TABLE FOR WINDOWS,GLAZED DOORS AND SKYUGHTS
- TABLE 102.3(2) U-VALUE DEFAULT TABLE FOR NONGLAZED DOORS
- TABLE 102.3(3) SHGC DEFAULT TABLE FOR FENESTRATION
- SECTION 103 ALTERNATE MATERIALS-METHODOF CONSTRUCTION, DESIGN ORINSULATING SYSTEMS
- SECTION 104 PLANS AND SPECIFICATIONS
- SECTION 105 INSPECTIONS
- SECTION 106 VALIDITY
- SECTION 107 REFERENCED STANDARDS
- CHAPTER 2:DEFINITIONS [Go to Page]
- SECTION 201 GENERAL DEFINITIONS
- CHAPTER 3: DESIGN CONDITIONS [Go to Page]
- SECTION 301 DESIGN CRITERIA
- SECTION 302 THERMAL DESIGN PARAMETERS [Go to Page]
- TABLE 302.1 EXTERIOR DESIGN CONDITIONS
- FIGURE 302.1(1)
- FIGURE 302.1(2)
- FIGURE 302.1(3)
- FIGURE 302.1(4)
- FIGURE 302.1(5)
- FIGURE 302.1(6)
- FIGURE 302.1(7)
- FIGURE 302.1(8)
- FIGURE 302.1(9)
- FIGURE 302.1(10)
- FIGURE 302.1(11)
- FIGURE 302.1(12)
- FIGURE 302.1(13)
- FIGURE 302.1(14)
- FIGURE 302.1(15)
- FIGURE 302.1(16)
- FIGURE 302.1(17)
- FIGURE 302.1(18)
- FIGURE 302.1(19)
- FIGURE 302.1(20)
- FIGURE 302.1(21)
- FIGURE 302.1(22)
- FIGURE 302.1(23)
- FIGURE 302.1(24)
- FIGURE 302.1(25)
- FIGURE 302.1(26)
- FIGURE 302.1(27)
- FIGURE 302.1(28)
- FIGURE 302.1(29)
- FIGURE 302.1(30)
- FIGURE 302.1(31)
- FIGURE 302.1(32)
- FIGURE 302.1(33)
- FIGURE 302.1(34)
- FIGURE 302.1(35)
- FIGURE 302.1(36)
- FIGURE 302.1(37)
- FIGURE 302.1(38)
- FIGURE 302.1(39)
- FIGURE 302.1(40)
- FIGURE 302.1(41)
- FIGURE 302.1(42)
- FIGURE 302.1(43)
- FIGURE 302.1(44)
- FIGURE 302.1(45)
- FIGURE 302.1(46)
- FIGURE 302.1(47)
- FIGURE 302.1(48)
- FIGURE 302.1(49)
- FIGURE 302.1(50)
- CHAPTER 4: RESIDENTIAL BUILDING DESIGN BY SYSTEMS ANALYSIS AND DESIGN OF BUILDINGS UTILIZING RENEWABLE ENERGY SOURCES [Go to Page]
- SECTION 401 SCOPE
- SECTION 402 SYSTEMS ANALYSIS [Go to Page]
- TABLE 402.1.1 (1) STANDARD DESIGN WALL ASSEMBLY U-VALUES
- TABLE 402.1.1 (2) STANDARD DESIGN FENESTRATION SYSTEM U-VALUES
- TABLE 402.1.3.5 HEATING AND COOLING CONTROLS
- SECTION 403 RENEWABLE ENERGY SOURCE ANALYSIS
- CHAPTER 5: RESIDENTIAL BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH [Go to Page]
- SECTION 501 SCOPE
- SECTION 502 BUILDING ENVELOPE REQUIREMENTS [Go to Page]
- TABLE 502.1.1(1) REQUIRED UwFORWALL WITH A HEAT CAPACITY EQUAL TO OR EXCEEDING 6 Btulft.2 . of. WITH INSULATION PLACED ON THE EXTERIOR OF THE WALL MASS
- TABLE 502.1.1 (2) REQUIRED UwFOR WALL WITH A HEAT CAPACITY EQUAL TO OR EXCEEDING 6 Btulft.2 . OF. WITH INSULATION PLACED ON THE INTERIOR OF THE WALL MASS
- TABLE 502.1.1(3) REQUIRED Uw FOR WALL WITH A HEAT CAPACITY EQUAL TO OR EXCEEDING 6 Btulft.2 . oF. WITH INTEGRAL INSULATION (INSULATION AND MASS MIXED, SUCH AS A LOG WALL)
- TABLE 502.28 HEATING AND COOLING CRITERIA
- TABLE 502.2.1.1 Fe VALUES FOR WALL SECllONS WITH STEEL STUDS PARALLEL PATH CORRECTION FACTORS
- EQUATION 5-1
- FIGURE 502.2(1) Vo WALLS - TYPE A-1 AND A-2 RESIDENTIAL BUILDINGS - HEATING
- FIGURE 502.2(2) Vo ROOF/CEILINGS - TYPE A-1 AND A-2 RESIDENTIAL BUILDINGS
- FIGURE 502.2(3) R-VALUES SLAB ON GRADE
- FIGURE 502.2(4) Uo VALUES - FLOOR OVER UNHEATED SPACES
- FIGURE 502.2(5) U-VALUES - CRAWL SPACE WALLS
- FIGURE 502.2(6) U-VALUES - BASEMENT WALLS
- FIGURE 502.2(7) TERMITE INFESTATION PROBABILITY MAP
- EQUATION 5-2
- EQUATION 5-3
- EQUATION 5-4
- TABLE 502.2.4(1) PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS TYPE A-1 RESIDENTIAL BUILDINGS, WINDOW AREA 8 PERCENT OF EXTERIOR WALL AREA
- TABLE 502.2.4(2) PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS TYPE A-1 RESIDENTIAL BUILDINGS, WINDOW AREA 12 PERCENT OF EXTERIOR WALL AREA
- TABLE 502.2.4(3) PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS TYPE A·1 RESIDENTIAL BUILDINGS, WINDOW AREA 15 PERCENT OF EXTERIOR WALL AREA
- TABLE 502.2.4(4) PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS TYPE A-1 RESIDENTIAL BUILDINGS, WINDOW AREA 18 PERCENT OF EXTERIOR WALL AREA
- TABLE 502.2.4(5) PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS TYPE A-1 RESIDENTIAL BUILDINGS, WINDOW AREA 20 PERCENT OF EXTERIOR WALL AREA
- TABLE 502.2.4(6) PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS TYPE A-1 RESIDENTIAL BUILDINGS, WINDOW AREA 25 PERCENT OF EXTERIOR WALL AREA
- TABLE 502.2.4(7) PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS TYPE A-2 RESIDENTIAL BUILDINGS, WINDOW AREA 20 PERCENT OF EXTERIOR WALL AREA
- TABLE 502.2.4(8) PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS TYPE A-2 RESIDENTIAL BUILDINGS, WINDOW AREA 25 PERCENT OF EXTERIOR WALL AREA
- TABLE 502.2.4(9) PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS TYPE A-2 RESIDENTIAL BUILDINGS, WINDOW AREA 30 PERCENT OF EXTERIOR WALL AREA
- TABLE 502.3.1 ALLOWABLE AIR INALTRATION RATES
- SECTION 503 BUILDING MECHANICAL SYSTEMS AND EQUIPMENT [Go to Page]
- TABLE 503.2 MINIMUM EQUIPMENT PERFORMANCE
- TABLE 503.3.3.1 MINIMUM PIPE INSULATION
- EQUATION 5-5
- TABLE 503.3.3.3MINIMUM DUCT INSULATION
- SECTION 504 SERVICE WATER HEATING [Go to Page]
- TABLE 504.2 MINIMUM PERFORMANCE OF WATER HEATING EQUIPMENT
- TABLE 504.7 MINIMUM PIPE INSULATION
- SECTION 505 ELECTRICAL POWER AND LIGHTING
- CHAPTER 6: BUILDING DESIGN FOR ALL COMMERCIAL BUILDINGS [Go to Page]
- SECTION 601 SCOPE
- CHAPTER 7: DESIGN BY ACCEPTABLE PRACTICE FOR COMMERCIAL BUILDINGS [Go to Page]
- SECTION 701 SCOPE
- SECTION 702 BUILDING ENVELOPE REQUIREMENTS [Go to Page]
- EQUATION 7-1
- TABLE 702.2(1) BUILDING ENVELOPE REQUIREMENTS" through" GLAZING AREA 10 PERCENT OR LESS OF ABOVE-GRADE WALL AREA
- TABLE 702.2(2) BUILDING ENVELOPE REQUIREMENTS· through e GLAZING AREA OVER 10 PERCENT BUT NOT GREATER THAN 25 PERCENT OF ABOVE-GRADE WALL AREA
- TABLE 702.2(3) BUILDING ENVELOPE REQUIREMENTSa through a GLAZING AREA OVER 25 PERCENT BUT NOT GREATER THAN 40 PERCENT OF ABOVE-GRADE WALL AREA
- SECTION 703 BUILDING MECHANICAL SYSTEMS [Go to Page]
- TABLE 703.3(1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EQUIPMENT EFACIENCY
- TABLE 703.3(2) UNITARY AND APPUED HEAT PUMPS, ELECTRICALLY OPERATED, MINIMUM EQUIPMENT EFFICIENCY
- TABLE 703.3(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS ELECTRICALLY OPERATED, MINIMUM EQUIPMENT EFFICIENCY
- TABLE 703.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
- TABLE 703.6 MINIMUM EQUIPMENT EFFICIENCY ECONOMIZER EXCEPTION
- SECTION 704 SERVICE WATER HEATING
- SECTION 705 LIGHTING SYSTEMS [Go to Page]
- TABLE 705.4 INTERIOR LIGHTING POWER
- TABLE 702.2(4) BUILDING ENVELOPE REQUIREMENTS CLIMATE ZONE
- TABLE 702.2(5) BUILDING ENVELOPE REQUIREMENTS CLIMATE ZONE
- TABLE 702.2(6) BUILDING ENVELOPE REQUIREMENTS· CLIMATE ZONE
- TABLE 702.2(7) BUILDING ENVELOPE REQUIREMENTS CLIMATE ZONE
- TABLE 702.2(8) BUILDING ENVELOPE REOUIREMENTS CLIMATE ZONE
- TABLE 702.2(9) BUILDING ENVELOPE REQUIREMENTS CLIMATE ZONE
- TABLE 702.2(10) BUILDING ENVELOPE REQUIREMENTS CLIMATE ZONE
- TABLE 702.2(11) BUILDING ENVELOPE REQUIREMENTS8- CLIMATE ZONE
- TABLE 702.2(12)BUILDING ENVELOPE REQUIREMENTS - CLIMATE ZONE
- TABLE 702.2(13)B UILDING ENVELOPE REQUIREMENTS· -CLIMATE ZONE
- TABLE 702.2(14) BUILDING ENVELOPE REQUIREMENTS8 CLIMATE ZONE
- TABLE 702,2(15) BUILDING ENVELOPE REQUIREMENTS8 -CLIMATE ZONE
- TABLE 702.2(16) BUILDING ENVELOPE REQUIREMENTS8 -CLIMATE ZONE
- TABLE 702_2(17) BUILDING ENVELOPE REQUIREMENTS -CLIMATE ZONE
- TABLE 702.2(18) BUILDING ENVELOPE REQUIREMENTS8 CLIMATE ZONE
- TABLE 702.2(19) BUILDING ENVELOPE REQUIREMENTS - CLIMATE ZONE 8
- TABLE 702.2(20) BUILDING ENVELOPE REQUIREMENTSa CLIMATE ZONE 9a
- TABLE 702.2(21) BUILDING ENVELOPE REQUIREMENTS 8 CLIMATE ZONE 9b
- TABLE 702.2(22) BUILDING ENVELOPE REQUIREMENTS B -CLIMATE ZONE 108
- TABLE 702.2(23) BUILDING ENVELOPE REQUIREMENTSB . CLIMATE ZONE lOb
- TABLE 702.2(24) BUILDING ENVELOPE REQUIREMENTS - CLIMATE ZONE 11
- TABLE 702.2(25) BUILDING ENVELOPE REQUIREMENTS8 CLIMATE ZONE 11b
- TABLE 702.2(26) BUILDING ENVELOPE REQUIREMENTSa • CLIMATE ZONE 12a
- TABLE 702.2(27) BUILDING ENVELOPE REQUIREMENTS 8• CLIMATE ZONE 12b
- TABLE 702.2(2B) BUILDING ENVELOPE REQUIREMENTS a -CLIMATE ZONE 138
- TABLE 702.2(29) BUILDING ENVELOPE REQUIREMENTS· - CLIMATE ZONE 13b
- TABLE 702.2(30) BUILDING ENVELOPE REQUIREMENTS8- CLIMATE ZONE 148
- TABLE 702_2(31) BUILDING ENVELOPE REQUIREMENTS - CLIMATE ZONE 14b
- TABLE 702.2(32) BUILDING ENVELOPE REQUIREMENTS - CLIMATE ZONE 15
- TABLE 702.2(33) BUILDING ENVELOPE REQUIREMENTS8- CLIMATE ZONE 16
- TABLE 702.2(34) BUILDING ENVELOPE REQUIREMENTS CLIMATE ZONE 17
- TABLE 702.2(35) BUILDING ENVELOPE REQUIREMENTS8- CLIMATE ZONE 18
- TABLE 702.2(36) BUILDING ENVELOPE REQUIREMENTS8 CLIMATE ZONE
- CHAPTER 8: REFERENCED STANDARDS [Go to Page]
- AAMA
- ANSI
- ARI
- ASHRAE
- ASME
- ASTM
- CODES
- DOE
- IES
- NAIMA
- NCMA
- NFRC
- NOAA
- NWWDA
- SMACNA
- UL
- APPENDIX [Go to Page]
- DETAIL 502.2.1.5 CRAWL SPACE WALL INSULATION
- TABLE 502.2.3.1(1) WALL ASSEMBLIES
- TABLE 502.2.3.1(2) WALL ASSEMBLIES
- TABLE 502.2.3.1(3) WALL ASSEMBLIES
- TABLE 502.2.3.2 ROOF/CEILING ASSEMBLIES
- TABLE 502.2.3.3 FLOOR ASSEMBLIES
- TABLE 502.2.3.5 CRAWL SPACE FOUNDATION WALL ASSEMBLIES
- TABLE 502.2.3.6 BASEMENT FOUNDATION WALL ASSEMBLIES
- INDEX [Go to Page]