Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(317)
(572)
(43)
(234)
(969)
(643)
(2114)
(64)
(92448)
(54)
(535)
(117)
(31)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6023)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • ASTM
    F1719-96(2002) Standard Specification for Image-Interactive Stereotactic and Localization Systems
    Edition: 2002
    $93.60
    Unlimited Users per year

Description of ASTM-F1719 2002

ASTM F1719-96(2002)

Historical Standard: ASTM F1719-96(2002) Standard Specification for Image-Interactive Stereotactic and Localization Systems

SUPERSEDED (see Active link, below)




ASTM F1719

1. Scope

1.1 This specification covers the combined use of stereotactic instruments or systems with imaging techniques, to direct a diagnostic or therapeutic modality into a specific target within the brain, based on localization information derived from such imaging techniques.

1.2 For the purpose of this specification, a stereotactic instrument or system is a guiding, aiming, or viewing device used in human neurosurgery for the purpose of manually directing a system or treating modality to a specific point within the brain by radiographic, imaging, or other visualization or identification of landmarks or targets or lesions.

1.3 Definition of Stereotactic Imaging Systems Types of imaging-guided systems all require three components: an imaging system, a stereotactic frame, or other physical device to identify the position of a point in space, and a method to relate image-generated coordinates to frame or device coordinates. See Performance Specification F 1266. The imaging technique must reliably and reproducibly generate data concerning normal or abnormal anatomic structures, or both, that can interface with the coordinate system of the stereotactic frame or other stereotactic system. The imaging-guided systems must allow accurate direction of therapeutic, viewing or diagnostic modalities to a specific point or volume or along a specific trajectory within the brain or often accurate estimation of structure size and location allowing biopsy, resection, vaporization, implantation, aspiration, or other manipulation, or combination thereof. The standards of accuracy, reproducibility, and safety must be met for the imaging modality, the stereotactic system, and the method of interface between the two, and for the system as a whole. The mechanical parts of the imaging modality and the stereotactic system should be constructed to allow maximal interaction with minimal interference with each other, to minimize imaging artifact and distortion, and minimize potential contamination of the surgical field.

1.4 General Types of Imaging that May Be Used With Stereotactic Systems Currently employed imaging modalities used in imaging-guided stereotactic systems include radiography, angiography, computed tomography, magnetic resonance imaging, ultrasound, biplane and multiplane digital subtraction angiography, and positron emission scanning. However, it is recognized that other modalities may be interfaced with currently available and future stereotactic systems and that new imaging modalities may evolve in the future. Standards for imaging devices will be dealt with in documents concerning such devices, and will not be addressed herein.

1.5 General types of diagnostic modalities include biopsy instruments, cannulas, endoscopes, electrodes, or other such instruments. Therapeutic modalities include, but are not limited to, heating, cooling, irradiation, laser, injection, tissue transplantation, mechanical or ultrasonic disruption, and any modality ordinarily used in cerebrospinal surgery.

1.6 Probe Any system or modality directed by stereotactic techniques, including mechanical or other probe, a device that is inserted into the brain or points to a target, and stereotactically directed treatment or diagnostic modality.

Note 1Examples presented throughout this specification are listed for clarity only; that does not imply that use should be restricted to the procedures or examples listed.

1.7 Robot A power-driven servo-controlled system for controlling and advancing a probe according to a predetermined targeting program.

1.8 Digitizer A device that is directed to indicate the position of a probe or point in stereotactic or other coordinates.

1.9 Frameless System A system that does not require a stereotactic frame, that identifies and localizes a point or volume in space by means of data registration, and a method to relate that point or volume to its representation derived from an imaging system.

1.10 The values stated in SI units are to be regarded as the standard.

1.11 The following precautionary caveat pertains only to the test method portion, Section , of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

F1266 Performance Specification for Cerebral Stereotactic Instruments


Keywords

Sterilization; Therapeutic modality; Anesthesia equipment--specifications; Biplane radiographic techniques; Calibration--medical/surgical devices/applications; Diagnostic modality; Image interactive localization systems; MRI (magnetic resonance imaging); Operating room safety; Positron emission tomography; Stereotactic instruments/systems;


ICS Code

ICS Number Code 11.040.99 (Other medical equipment)


DOI: 10.1520/F1719-96R02

ASTM International is a member of CrossRef.


This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $971.23 Buy
VAR
ASTM
[+] $1,618.05 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X