Cart (0)
  • No items in cart.
Subtotal
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(316)
(569)
(43)
(234)
(969)
(643)
(1935)
(64)
(91921)
(54)
(535)
(117)
(28)
(20)
(19)
(92193)
(3)
(17)
(1)
(351)
(298)
(6023)
(239)
(16)
(5)
(1619)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • ASTM
    F1190-11 Standard Guide for Neutron Irradiation of Unbiased Electronic Components
    Edition: 2011
    $93.60
    Unlimited Users per year

Description of ASTM-F1190 2011

ASTM F1190 - 11

Standard Guide for Neutron Irradiation of Unbiased Electronic Components

Active Standard ASTM F1190 | Developed by Subcommittee: F01.11

Book of Standards Volume: 10.04




ASTM F1190

Significance and Use

Semiconductor devices can be permanently damaged by reactor spectrum neutrons ( 1, 2 ) . The effect of such damage on the performance of an electronic component can be determined by measuring the component s electrical characteristics before and after exposure to fast neutrons in the neutron fluence range of interest. The resulting data can be utilized in the design of electronic circuits that are tolerant of the degradation exhibited by that component.

This guide provides a method by which the exposure of silicon and gallium arsenide semiconductor devices to neutron irradiation may be performed in a manner that is repeatable and which will allow comparison to be made of data taken at different facilities.

For semiconductors other than silicon and gallium arsenide, applicable validated 1-MeV damage functions are not available in codified National standards. In the absence of a validated 1-MeV damage function, the non-ionizing energy loss (NIEL) or the displacement kerma, as a function incident neutron energy, normalized to the response in the 1 MeV energy region, may be used as an approximation. See Practice E722 for a description of the method used to determine the damage functions in Si and GaAs ( 3 ).

1. Scope

1.1 This guide strictly applies only to the exposure of unbiased silicon (Si) or gallium arsenide (GaAs) semiconductor components (integrated circuits, transistors, and diodes) to neutron radiation from a nuclear reactor source to determine the permanent damage in the components. Validated 1-MeV displacement damage functions codified in National Standards are not currently available for other semiconductor materials.

1.2 Elements of this guide, with the deviations noted, may also be applicable to the exposure of semiconductors comprised of other materials except that validated 1-MeV displacement damage functions codified in National standards are not currently available.

1.3 Only the conditions of exposure are addressed in this guide. The effects of radiation on the test sample should be determined using appropriate electrical test methods.

1.4 This guide addresses those issues and concerns pertaining to irradiations with reactor spectrum neutrons.

1.5 System and subsystem exposures and test methods are not included in this guide.

1.6 This guide is applicable to irradiations conducted with the reactor operating in either the pulsed or steady-state mode. The range of interest for neutron fluence in displacement damage semiconductor testing range from approximately 10 9 to 10 16 1-MeV n/cm 2 .

1.7 This guide does not address neutron-induced single or multiple neutron event effects or transient annealing.

1.8 This guide provides an alternative to Test Method 1017.3, Neutron Displacement Testing, a component of MIL-STD-883 and MIL-STD-750. The Department of Defense has restricted use of these MIL-STDs to programs existing in 1995 and earlier.

1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

E264 Test Method for Measuring Fast-Neutron Reaction Rates by Radioactivation of Nickel

E265 Test Method for Measuring Reaction Rates and Fast-Neutron Fluences by Radioactivation of Sulfur-32

E668 Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices

E720 Guide for Selection and Use of Neutron Sensors for Determining Neutron Spectra Employed in Radiation-Hardness Testing of Electronics

E721 Guide for Determining Neutron Energy Spectra from Neutron Sensors for Radiation-Hardness Testing of Electronics

E722 Practice for Characterizing Neutron Fluence Spectra in Terms of an Equivalent Monoenergetic Neutron Fluence for Radiation-Hardness Testing of Electronics

E1249 Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources

E1250 Test Method for Application of Ionization Chambers to Assess the Low Energy Gamma Component of Cobalt-60 Irradiators Used in Radiation-Hardness Testing of Silicon Electronic Devices

E1854 Practice for Ensuring Test Consistency in Neutron-Induced Displacement Damage of Electronic Parts

E1855 Test Method for Use of 2N2222A Silicon Bipolar Transistors as Neutron Spectrum Sensors and Displacement Damage Monitors

E2450 Practice for Application of CaF2(Mn) Thermoluminescence Dosimeters in Mixed Neutron-Photon Environments

F980 Guide for Measurement of Rapid Annealing of Neutron-Induced Displacement Damage in Silicon Semiconductor Devices

F1892 Guide for Ionizing Radiation (Total Dose) Effects Testing of Semiconductor Devices

Other Documents

DASIAC SR-94-009, Ap Guide to Nuclear Weapons Effects Simulation Facilities and Techniques Available from Defense Special Weapons Agency, Washington, DC 20305-1000.

Keywords

dosimetry; electronic component; equivalent monoenergetic neutron fluence; fast burst reactor (FBR); gallium arsenide; gamma dose; gamma effects; irradiation; neutron fluence; neutron flux; nickel; 1 MeV equivalent fluence; radiation; reactor; semiconductor; silicon; sulfur; thermoluminescent dosimeter (TLD); TRIGA-type reactor: Destructive testing--semiconductors; Dosimetry; Electrical conductors (semiconductors); Electronic devices/instruments/equipment; Equivalent monoenergetic neutron fluence; Exposure tests--electronic components/devices; Fast burst reactors (FBR); Gallium arsenide; Gamma radiation; Germanium--semiconductor applications; Irradiance/irradiation--semiconductors; 1MeV equivalent fluence; Neutron radiation; Nickel electrical/electronic applications; Radiation exposure--electronic components/devices; Reactors; Semiconductor technology; Silicon semiconductors; Sulfur; Thermal neutron radiation; Thermoluminescent dosimeter (TLD); TRIGA-type reactors;


ICS Code

ICS Number Code 31.020 (Electronic components in general); 31.080.01 (Semi-conductor devices in general)


DOI: 10.1520/F1190-11

ASTM International is a member of CrossRef.

ASTM F1190

The following editions for this book are also available...

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $1,164.67 Buy
VAR
ASTM
[+] $1,737.94 Buy
VAR
ASTM
[+] $971.23 Buy
VAR
ASTM
[+] $2,452.26 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.