Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(317)
(572)
(43)
(234)
(969)
(643)
(1945)
(64)
(91921)
(54)
(535)
(117)
(31)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6023)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • ASTM
    E2112-18b Standard Practice for Installation of Exterior Windows, Doors and Skylights
    Edition: 2018
    $169.73
    Unlimited Users per year

Description of ASTM-E2112 2018

ASTM E2112-18b

Historical Standard: Standard Practice for Installation of Exterior Windows, Doors and Skylights




ASTM E2112

Scope

1.1 This practice covers the installation of fenestration products in new and existing construction. For the purpose of this practice, fenestration products shall be limited to windows, sliding patio-type doors, swinging patio type doors, and skylights, as used primarily in residential and light commercial buildings.

1.2 This practice assumes that the installer possesses basic woodworking skills and an understanding of wall and roof construction, sheet metal work, and joint sealant practices.

1.3 This practice attempts to instruct and familiarize the installer with the concepts of both Barrier Systems and Membrane/Drainage Systems, in order to ensure the continuity of the building envelope. This practice attempts to educate the installer, builder, architect, and other users in the identification and understanding of the water shedding system of the building envelope.

1.4 This practice covers the installation process from pre-installation procedures through post-installation procedures, for single units or factory-mulled multiple units in a single opening. It does not cover the fabrication or assembly of multiple units, whether such fabrication takes place in a factory or at the intended installation site. The installer should check with the manufacturer of factory-assembled units for instructions for anchoring. When using field-mulled units, follow manufacturer's recommendations and make certain that they meet applicable codes. This practice does not cover the selection of appropriate fenestration products for a given application, nor the selection of other products or systems for use in the installation.

1.5 This practice provides minimum requirements that will help to accomplish the installation of fenestration products in an effective manner. Actual conditions in buildings vary greatly and, in some cases, substantial additional precautions may be required. In the event that the manufacturer's installation instructions provided with the product conflict with requirements of this practice, the manufacturer's instructions shall prevail. This practice is not intended to limit or exclude other new procedures that may refine or further improve the effectiveness of fenestration installation.

1.5.1 This practice is intended to be used for background information in order to develop training manuals and training programs. Further, this practice attempts to consolidate and unify the various steps of construction, tying together the various trades involved with the continuity between fenestration products and the building envelope.

1.6 The text of this practice references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this practice.

1.7 This standard has not been created to address all issues related to every possible installation situation one might experience in the field. Furthermore, this practice does not purport to provide fail-safe installation methods, assurance or protection against installation deficiencies, or a standard by which architects can specify or ensure delivered performance.

Note 1: There are no ISO standards covering the primary subject matter of this practice.

1.8 Design Professional—This practice is not intended to limit the role and authority of a registered design professional to select a method of installation or to change, modify, or develop other methods of installation to meet the specific requirements of a building project for a particular location. A design professional retains the authority to prepare construction documents indicating window/door/skylight installations integrated with the water-resistive barrier.

1.9 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.10 This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and to determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 5, Related Procedures. Where a lead hazard is known or suspected, refer to ASTM Standards on Lead Hazards Associated with Buildings and to applicable state and federal regulations. Where an asbestos hazard is known or suspected, refer to the ASTM Manual on Asbestos Control, and to applicable state and federal regulations.

1.11 Table of Contents:

 

Section

 

Scope

1

 Table of Contents

1.11

Referenced Documents

2

Terminology

3

 Definitions

3.1

 Description of Terms Specific to this Standard

3.2

 Abbreviations

3.3

Significance and Use

4

Related Issues and Procedures

5

 Continuity with the Weather Barrier Systems

5.1

 Joints and Anchorages

5.2

 Moisture Entrapment

5.3

 Weather Resistant Barrier

5.4

 Weatherability

5.5

 Construction Sequence

5.6

 Construction Damage

5.7

 Inspection

5.8

 Rough Opening

5.9

  Rough Opening Size

5.9.1

  Insulating or Filling the Rough Opening Gap

5.9.2

 Materials Protection

5.10

 Cleaning and Maintenance

5.11

 Dissimilar Materials

5.12

 Flashing Requirements

5.13

 Fastening Systems/Anchorage

5.14

 Shimming

5.15

 Panning Systems and Subsills for Weatherability

5.16

 Pre-Installation Procedures

5.17

 Sealants—Selection and Use

5.18

 Window Cleaner Anchors and Related Safety
  Hardware

5.19

Continuity Between the Fenestration Products and
 Other Components of the Building Envelope

6

Water Shedding Strategies of Wall and Roof Systems

7

 Concept of Surface Barrier Systems and
  Membrane/Drainage Systems

7.1

  Surface Barrier Systems

7.1.1

  Membrane/Drainage Systems

7.1.2

 Identification of Systems

7.2

Installation Methods For Windows

8

 Windows in Walls Utilizing a Membrane/Drainage
  System

8.1

  Windows with Perimeter Mounting Flanges
   (Nail Fins) in Drainage Type
   Wall Construction

8.1.1

   Flange Types

8.1.1.1

   Selection of Installation Method

8.1.1.2

    Method A

8.1.1.3.1

    Method B

8.1.1.3.2

    Method A1

8.1.1.3.3

    Method B1

8.1.1.3.4

  Non-Finned Windows in Membrane/Drainage
   Type Walls

8.1.2

 Windows in Walls Utilizing a Barrier Wall System
  (Sealant Method)

8.2

 Windows in Walls Utilizing an Exterior Barrier System
  (EIFS or Direct Applied)

8.3

 Special Considerations

8.4

  Aluminum Framed Windows

8.4.1

  Vinyl Framed Windows

8.4.2

 Replacement Window Installation

8.5

  Partial Window Replacement for Existing Integral
   Flange Windows

8.5.1

  Partial Replacement of Mill Shop Wood Windows

8.5.2

  Complete Window Replacement

8.5.3

   Destructive Window Replacement (Fin Type)

8.5.3.1

   Non-Destructive Window Replacement
    (Non-Fin Type)

8.5.3.2

Installation Methods for Doors

9

 Doors in Walls Utilizing a Membrane/Drainage System

9.1

  Doors with Perimeter Mounting Flanges
   (Nailing Fins) in Drainage Type
   Wall Construction

9.1.1

   Flange Types

9.1.1.1

   Selection of Installation Method

9.1.1.2

    Method A

9.1.1.4.1

    Method B

9.1.1.4.2

    Method A1

9.1.1.4.3

    Method B1

9.1.1.4.4

  Hinged Swing (Non-finned) Doors in Membrane/
   Drainage Type Walls

9.1.2

Installation Methods for Skylights

10

 Product Types

10.1

 Flashing Procedures

10.2

 Aluminum/Copper Sheet Flashing

10.3

 Aluminum/Copper Step Flashing (Fabricated or
  Engineered)

10.4

 Membrane Flashing

10.5

Post-Installation Procedures

11

Keywords

12

Air Barrier Foam Sealant Used in the Rough
 Opening Gap

Annex A1

Emergency Escape and Rescue Requirements

Annex A2

Minimum Height Requirements for Interior Height of
 Pan Flashing

Annex A3

Sealants

Annex A4

Window/Door Flashing Types

Appendix X1

Cautions for Installation

Appendix X2

Bibliography/Other Referenced Installation Guides

Appendix X3

1.12 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


Keywords

barrier system; continuity of weather barrier; door anchorage, window; door flashing, window; door installation; door perimeter sealing; liquid-applied flashing; membrane drainage wall system, window; self-adhered flashing (SAF); skylight installation; weather resistance; weather-resistive barrier; window installation;


ICS Code

ICS Number Code 91.060.50 (Doors and windows)


DOI: 10.1520/E2112-18B

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $1,040.75 Buy
VAR
ASTM
[+] $1,636.18 Buy
VAR
ASTM
[+] $10,801.41 Buy
VAR
ASTM
[+] $5,812.65 Buy
VAR
ASTM
[+] $3,560.85 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X