1. Scope
1.1 This test method describes the requirements for sample preparation, tensile testing, and results calculation of flat fiber reinforced polymer (FRP) composite materials used for the strengthening of structures made of materials such as metals, timber, masonry, and reinforced concrete. The method may be used to determine the tensile properties of wet lay-up and pre-impregnated FRP composites fabricated on site or manufactured in a factory setting. The FRP composite may be of either unidirectional (0-degrees) or cross-ply (0/90 type) reinforcement. For cross-ply laminates, the construction may be achieved using multiple-layers of unidirectional fibers at either 0 or 90 degrees, or one or more layers of stitched or woven 0/90 fabrics. The composite material forms are limited to continuous fiber or discontinuous fiber-reinforced composites in which the laminate is balanced and symmetric with respect to the test direction. The method only covers the determination of the tensile properties of the FRP composite material. Other components used to attach the FRP material to the substrate, such as the primer, putty, and adhesive in externally bonded strengthening systems, are excluded from the sample preparation and testing detailed in this document. This test method refers to Test Method D3039/D3039M for conduct of the tests.
1.2 The values stated in either SI units or inch-pound units are to be regarded as standard. Within the text, the inch-pound units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system must be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D883 Terminology Relating to Plastics
D3039/D3039M Test Method for Tensile Properties of Polymer Matrix Composite Materials
D3878 Terminology for Composite Materials
D5229/D5229M Test Method for Moisture Absorption Properties and Equilibrium Conditioning of Polymer Matrix Composite Materials
D5687/D5687M Guide for Preparation of Flat Composite Panels with Processing Guidelines for Specimen Preparation
E6 Terminology Relating to Methods of Mechanical Testing
E122 Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or Process
E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods
E456 Terminology Relating to Quality and Statistics
Keywords
composite materials; modulus of elasticity; pre-cured FRP system; tensile properties; tensile strength; wet lay-up FRP system; Composite materials; Fiber reinforced polymers; Modulus of elasticity; Tensile properties/testing ;
ICS Code
ICS Number Code 83.120 (Reinforced plastics)
DOI: 10.1520/D7565_D7565M-09