Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(317)
(572)
(43)
(234)
(969)
(643)
(2114)
(64)
(92448)
(54)
(535)
(117)
(31)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6023)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • ASTM
    D7352-07(2012) Standard Practice for Direct Push Technology for Volatile Contaminant Logging with the Membrane Interface Probe (MIP)
    Edition: 2012
    $103.58
    Unlimited Users per year

Description of ASTM-D7352 2012

ASTM D7352 - 07(2012)

Standard Practice for Direct Push Technology for Volatile Contaminant Logging with the Membrane Interface Probe (MIP)

Active Standard ASTM D7352 | Developed by Subcommittee: D18.21

Book of Standards Volume: 04.09




ASTM D7352

Significance and Use

5.1 The MIP system provides a timely and cost effective way ( 4 ) for delineation of volatile organic contaminants (for example, benzene, toluene, solvents, trichloroethylene, tetrachloroethylene) with depth ( 5 , 6 ) . Recent investigation ( 2 ) has found the MIP can be effective in locating zones where dense nonaqueous phase liquids (DNAPL) may be present. MIP provides real-time measurement for optimizing selection of sample locations when using a dynamic work plan. By identifying the depth at which a contaminant is located, a more representative sample of soil or water can be collected.

5.2 Correlation of a series of MIP logs across a site can provide 2-D and 3-D definition of the contaminant plume. When lithologic logs are obtained (EC, CPT, etc.) with the MIP data, contaminant migration pathways may be defined.

5.3 The MIP logs provide a detailed record of contaminant distribution in the saturated and unsaturated formations. A proportion of the chlorinated and non-chlorinated volatile organic contaminants in the sorbed, aqueous, or gaseous phases partition through the membrane for detection up hole.

5.4 The data obtained from application of this practice may be used to guide soil (Guide D6282 ) and groundwater sampling (Guide D6001 ) or placement of long-term monitoring wells (Guide D6724 ).

5.5 MIP data can be used to optimize site remediation by knowing the depth distribution of volatile organic contaminants. For example, materials injected for remediation are placed at correct depths in the formation.

5.6 This practice also may be used as a means of evaluating remediation performance. MIP can provide a cost-effective way to monitor the progress of remediation. When properly performed at suitable sites, logging locations can be compared from the initial investigation to the monitoring of the contaminant under remediation conditions.

Note 1 The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Practitioners that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors. Practice D3740 was developed for agencies engaged in the testing and/or inspection of soils and rock. As such, it is not totally applicable to agencies performing this practice. However, users of this practice should recognize that the framework of Practice D3740 is appropriate for evaluating the quality of an agency performing this practice. Currently there is no known qualifying national authority that inspects agencies that perform this practice.

1. Scope

1.1 This standard practice describes a method for rapid delineation of volatile organic contaminants (VOC) in the subsurface using a membrane interface probe. Logging with the membrane interface probe is usually performed with direct push equipment.

1.2 This standard practice describes how to obtain a real time vertical log of volatile organic contaminants with depth. The data obtained is indicative of the total volatile organic contaminant concentration in the subsurface at depth.

1.3 Other sensors, such as electrical conductivity, fluorescence detectors, and cone penetration tools may be included to provide additional information. The use of a lithologic logging tool is highly recommended to define hydrostratigraphic conditions, such as migration pathways, and to guide confirmation sampling.

1.4 Limitations The MIP system does not provide specificity of analytes. This tool is to be used as a total volatile organic contaminant-screening tool. Soil and/or water sampling (Guides D6001 , D6282 , D6724 , and Practice D6725 ) must be performed to identify specific analytes and exact concentrations. Only VOCs are detected by the MIP system in the subsurface. Detection limits are subject to the selectivity of the gas phase detector applied and characteristics of the formation being penetrated (for example, clay and organic carbon content).

1.5 This practice offers a set of instructions for performing one or more specific operations. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this practice may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without the consideration of a projects many unique aspects. The word standard in the title means that the document has been approved through the ASTM consensus process.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

D653 Terminology Relating to Soil, Rock, and Contained Fluids

D5299 Guide for Decommissioning of Groundwater Wells, Vadose Zone Monitoring Devices, Boreholes, and Other Devices for Environmental Activities

D6001 Guide for Direct-Push Ground Water Sampling for Environmental Site Characterization

D6282 Guide for Direct Push Soil Sampling for Environmental Site Characterizations

D6724 Guide for Installation of Direct Push Groundwater Monitoring Wells

D6725 Practice for Direct Push Installation of Prepacked Screen Monitoring Wells in Unconsolidated Aquifers

E355 Practice for Gas Chromatography Terms and Relationships


Keywords

CPT; direct push; electrical conductivity; membrane interface probe; MIP; soil investigations; VOC; volatile organic contaminants;


ICS Code

ICS Number Code 13.080.05 (Examination of soil in general)


DOI: 10.1520/D7352-07R12

ASTM International is a member of CrossRef.

ASTM D7352

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $1,235.20 Buy
VAR
ASTM
[+] $10,801.41 Buy
VAR
ASTM
[+] $5,812.65 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X