ASTM D4913-00
Historical Standard: ASTM D4913-00 Standard Practice for Determining Concentration of Hydrogen Sulfide by Direct Reading, Length of Stain, Visual Chemical Detectors
SUPERSEDED (see Active link, below)
ASTM D4913
1. Scope
1.1 This practice covers the detection of hydrogen sulfide gas by visual chemical detectors. Included under visual chemical detectors are: short-term detector tubes (1) , long-term detector tubes (2) , and length-of-stain dosimeters (3) . Diffusion tubes are not included under this practice because they are not direct reading, and spot tests are not included because of their poor accuracy. The results are immediately available by visual observation, thus no analytical equipment is needed.
1.2 This practice reflects the current state-of-the-art for commercially available visual length-of-stain detectors for hydrogen sulfide. Any mention of a specific manufacturer in the text or references does not constitute an endorsement by ASTM.
1.3 The values stated in SI units are to be regarded as the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D1356 Terminology Relating to Sampling and Analysis of Atmospheres
D3686 Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method)
D4490 Practice for Measuring the Concentration of Toxic Gases or Vapors Using Detector Tubes
D4599 Practice for Measuring the Concentration of Toxic Gases or Vapors Using Length-of-Stain Dosimeters
Other Documents
ThresholdLimit Values for Chemical Substances in the Work Environment Adopted by the American Conference of Governmental Industrial Hygienists, latest issue Available from American Conference of Governmental Industrial Hygienists, Inc. (ACGIH), 1330 Kemper Meadow Dr., Cincinnati, OH 45240, http://www.acgih.org.ANSI Standard
Keywords
air monitoring; detector tubes; hydrogen sulfide; length-of-stain dosimeters; sampling and analysis; workplace atmospheres; Air analysis; Air monitoring; Atmospheric analysis; Chemical detectors; Color; Detectors; Dosimetry; Hydrogen sulfide--atmospheric analysis; Length-of-stain detector tubes; Visual examination;
ICS Code
ICS Number Code 71.060.99 (Other inorganic chemicals)
DOI: 10.1520/D4913-00