Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Enter keywords for book title search
Search book content
Enter keywords for book content search
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(317)
(572)
(43)
(234)
(969)
(643)
(1945)
(64)
(91921)
(54)
(535)
(117)
(31)
(20)
(19)
(92811)
(3)
(17)
(1)
(351)
(300)
(6023)
(239)
(16)
(5)
(1621)
(16)
(18)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(23)
(26)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(31)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Technical Bulletin
 All
  • ASTM
    D4105-96(2008) Standard Test Method for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Nonleaky Confined Aquifers by the Modified Theis Nonequilibrium Method
    Edition: 2008
    $93.60
    Unlimited Users per year

Description of ASTM-D4105 2008

ASTM D4105 - 96(2008)

Standard Test Method for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Nonleaky Confined Aquifers by the Modified Theis Nonequilibrium Method

Active Standard ASTM D4105 | Developed by Subcommittee: D18.21

Book of Standards Volume: 04.08




ASTM D4105

Significance and Use

Assumptions :

Well discharges at a constant rate, Q .

Well is of infinitesimal diameter and fully penetrates the aquifer, that is, the well is open to the full thickness of the aquifer.

The nonleaky aquifer is homogeneous, isotropic, and areally extensive. A nonleaky aquifer receives insignificant contribution of water from confining beds.

Discharge from the well is derived exclusively from storage in the aquifer.

The geometry of the assumed aquifer and well conditions are shown in Fig. 1.

Implications of Assumptions :

Implicit in the assumptions are the conditions of radial flow. Vertical flow components are induced by a control well that partially penetrates the aquifer, that is, not open to the aquifer through its full thickness. If the control well does not fully penetrate the aquifer, the nearest piezometer or partially penetrating observation well should be located at a distance, r , beyond which vertical flow components are negligible, where according to Reed (5)

This section applies to distance-drawdown calculations of transmissivity and storage coefficient and time-drawdown calculations of storage coefficient. If possible, compute transmissivity from time-drawdown data from wells located within a distance, r , of the pumped well using data measured after the effects of partial penetration have become constant. The time at which this occurs is given by Hantush (6) by:

Fully penetrating observation wells may be placed at less than distance r from the control well. Observation wells may be on the same or on various radial lines from the control well.

The Theis method assumes the control well is of infinitesimal diameter. Also, it assumes that the water level in the control well is the same as in the aquifer contiguous to the well. In practice these assumptions may cause a difference between the theoretical drawdown and field measurements of drawdown in the early part of the test and in and near the control well. Control well storage is negligible after a time, t , given by the following equation after weeks (7) .

where:
r c = the radius of the control well in the interval that includes the water level changes.

Application of Theis Nonequilibrium Method to Unconfined Aquifers :

Although the assumptions are applicable to confined conditions, the Theis solution may be applied to unconfined aquifers if drawdown is small compared with the saturated thickness of the aquifer or if the drawdown is corrected for reduction in thickness of the aquifer and the effects of delayed gravity yield are small.

Reduction in Aquifer Thickness In an unconfined aquifer, dewatering occurs when the water levels decline in the vicinity of a pumping well. Corrections in drawdown need to be made when the drawdown is a significant fraction of the aquifer thickness as shown by Jacob (8) . The drawdown, s , needs to be replaced by s ? , the drawdown that would occur in an equivalent confined aquifer, where:

Gravity Yield Effects In unconfined aquifers, delayed gravity yield effects may invalidate measurements of drawdown during the early part of the test for application to the Theis method. Effects of delayed gravity yield are negligible in partially penetrating observation wells at a distance, r , from the control well, where:


after the time, t , as given in the following equation from Neuman (9) :

where:
S y = the specific yield.

For fully penetrating observation wells, the effects of delayed yield are negligible at the distance, r , in Eq 11 after one tenth of the time given in the Eq 12.


FIG. 1 Cross Section Through a Discharging Well in a Nonleaky Confined Aquifer

1. Scope

1.1 This test method covers an analytical procedure for determining transmissivity and storage coefficient of a nonleaky confined aquifer under conditions of radial flow to a fully penetrating well of constant flux. This test method is a shortcut procedure used to apply the Theis nonequilibrium method. The Theis method is described in Test Method D4106 .

1.2 This test method is used in conjunction with the field procedure given in Test Method D4050 .

1.3 Limitations The limitations of this test method are primarily related to the correspondence between the field situation and the simplifying assumptions of this test method (see 5.1). Furthermore, application is valid only for values of u less than 0.01 ( u is defined in Eq 2, in 8.6).

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

D653 Terminology Relating to Soil, Rock, and Contained Fluids

D4043 Guide for Selection of Aquifer Test Method in Determining Hydraulic Properties by Well Techniques

D4050 Test Method for (Field Procedure) for Withdrawal and Injection Well Tests for Determining Hydraulic Properties of Aquifer Systems

D4106 Test Method for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Nonleaky Confined Aquifers by the Theis Nonequilibrium Method


Keywords

aquifer tests; aquifers; confined aquifers; control wells; groundwater; hydraulic properties; observation wells; storage coefficient; transmissivity; unconfined aquifers; Aquifers; Coefficient of storage; Confined aquifers; Control wells; Field testing--ground water/aquifers; Ground water; Hydraulic conductivity/transmissivity; Observation wells; Storativity; Theis methods of analysis; Transmissivity and reflectivity; Unconfined/unconsolidated aquifers;


ICS Code

ICS Number Code 93.160 (Hydraulic construction)


DOI: 10.1520/D4105-96R08

ASTM International is a member of CrossRef.

ASTM D4105

This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $1,373.22 Buy
VAR
ASTM
[+] $10,801.41 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X