FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Technical Bulletin
All
|
Content DescriptionThe explanatory material, detailed information, figures, and examples contained within this User’s Manual are provided to aid the user in designing, installing, and operating buildings in accordance with ASHRAE Standard 62.1-2010. This Manual does not reproduce the requirements of the standard, but rather paraphrases and explains them. Intended to be used in conjunction with the standard, this Manual: Offers information on the intent and application of Standard 62.1; Explains the standard through the use of sample calculations and examples; Encourages the user to apply the principles of good indoor air quality and effective ventilation when designing buildings and building systems; Provides useful reference material to assist designers in efficiently completing a successful and compliant design; Gives guidance to building operation and maintenance personnel. This Manual also instructs the user in the application of tools used for compliance with Standard 62.1-2010. In particular, three newly revised 62MZCalc spreadsheets are distributed with this User\'s Manual that assist in the Ventilation Rate Procedure calculations. This User’s Manual is intended to be used by: Architects and engineers who must apply the standard to the design of their buildings; Those manufacturers of systems and components who choose to provide the industry with complying equipment; Plan examiners and field inspectors who will be charged with enforcing the standard in areas where it is adopted as code; General and specialty contractors who must construct buildings in compliance with the standard; and Operators and maintainers who must ensure the compliance of the building throughout its lifespan. Keywords: ventilation, user\'s manual, instruction, compliance, indoor air quality This book also exists in the following packages...Subscription InformationMADCAD.com ASHRAE subscriptions are annual and access is concurrency based (number of people that can access the subscription at any given time).
Some features of MADCAD.com ASHRAE Subscriptions are:
- Floating concurrency model: Set your concurrency level and share your ASHRAE Subscriptions among your offices enterprise-wide.
- Immediate Access: As soon as the transaction is completed, your ASHRAE Subscription will be ready for access.
For any further information on MADCAD.com ASHRAE Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASHRAEASHRAE, founded in 1894, is a building technology society with more than 50,000 members worldwide. The Society and its members focus on building systems, energy efficiency, indoor air quality and sustainability within the industry. Through research, standards writing, publishing and continuing education, ASHRAE shapes tomorrow’s built environment today.
ASHRAE was formed as the American Society of Heating, Refrigerating and Air-Conditioning Engineers by the merger in 1959 of American Society of Heating and Air-Conditioning Engineers (ASHAE) founded in 1894 and The American Society of Refrigerating Engineers (ASRE) founded in 1904.
|
GROUPS
|