FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Technical Bulletin
All
|
Content Description"Prepared by the Design of Steel Transmission Towers Standards Committee of the Codes and Standards Activities Division of the Structural Engineering Institute of ASCE This standard provides requirements for the design, fabrication, and testing of members and connections for latticed steel electrical transmission structures. Covering guyed and self-supporting structures, these requirements are applicable to hot-rolled and cold-formed steel shapes. The standard specifies the design criteria for structure components—members, connections, and guys—to resist design-factored loads at stresses approaching yielding, buckling, or fracture. This new edition, which replaces the previous Standard ASCE 10-97, presents minor changes to the design requirements and introduces new sections on redundant members, welded angles, anchor bolts with base plates on leveling nuts, and post angle member splices. Topics include: loading, geometry, and analysis; design of members, including compression members, tension members, and beams; design of connections, including fasteners, minimum distances, and attachment holes; detailing and fabrication; full-scale structure testing; structural members and connections used in foundations; and quality assurance and quality control. A detailed commentary contains explanatory and supplementary information to assist users of the standard. In addition, one appendix offers 17 design examples, and a new appendix offers guidance for evaluating older (legacy) electrical transmission towers. Standard ASCE/SEI 10-15 "Prepared by the Design of Steel Transmission Towers Standards Committee of the Codes and Standards Activities Division of the Structural Engineering Institute of ASCE This standard provides requirements for the design, fabrication, and testing of members and connections for latticed steel electrical transmission structures. Covering guyed and self-supporting structures, these requirements are applicable to hot-rolled and cold-formed steel shapes. The standard specifies the design criteria for structure components—members, connections, and guys—to resist design-factored loads at stresses approaching yielding, buckling, or fracture. This new edition, which replaces the previous Standard ASCE 10-97, presents minor changes to the design requirements and introduces new sections on redundant members, welded angles, anchor bolts with base plates on leveling nuts, and post angle member splices. Topics include: loading, geometry, and analysis; design of members, including compression members, tension members, and beams; design of connections, including fasteners, minimum distances, and attachment holes; detailing and fabrication; full-scale structure testing; structural members and connections used in foundations; and quality assurance and quality control. A detailed commentary contains explanatory and supplementary information to assist users of the standard. In addition, one appendix offers 17 design examples, and a new appendix offers guidance for evaluating older (legacy) electrical transmission towers. Standard ASCE/SEI 10-15 is a primary reference for structural engineers designing latticed steel electrical transmission structures, as well as for other engineers, inspectors, and utility officials involved in the electric power transmission industry." is a primary reference for structural engineers designing latticed steel electrical transmission structures, as well as for other engineers, inspectors, and utility officials involved in the electric power transmission industry."This book also exists in the following packages...Subscription InformationMADCAD.com ASCE subscriptions are annual and access is concurrency based (number of people that can access the subscription at any given time).
Some features of MADCAD.com ASCE Subscriptions are:
- Floating concurrency model: Set your concurrency level and share your ASCE Subscriptions among your offices enterprise-wide.
- Immediate Access: As soon as the transaction is completed, your ASCE Subscription will be ready for access.
For any further information on MADCAD.com ASCE Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASCEFounded in 1852, the American Society of Civil Engineers (ASCE) represents more than 140,000 members of the civil engineering profession worldwide and is America's oldest national engineering society. ASCE's Mission Provide essential value to our members and partners, advance civil engineering, and serve the public good. |
GROUPS
|