FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Technical Bulletin
All
|
Content DescriptionThis standard prescribes procedures for the seismic analysis and design of liquid-containing concrete structures. These procedures address the loading side of seismic design and are intended to complement ACI 350-06, Section 1.1.8 and Chapter 21. INTRODUCTION The following paragraphs highlight the development of this standard and its evolution to the present format: From the time it embarked on the task of developing an ACI 318-dependent code, ACI Committee 350 decided to expand on and supplement Chapter 21, “Special Provisions for Seismic Design,” to provide a set of thorough and comprehensive procedures for the seismic analysis and design of all types of liquid-containing environmental concrete structures. The committee’s decision was influenced by the recognition that liquid-containing structures are unique structures whose seismic design is not adequately covered by the leading national codes and standards. A seismic design subcommittee was appointed with the charge to implement the committee’s decision. The seismic subcommittee’s work was guided by two main objectives: 1. To produce a self-contained set of procedures that would enable a practicing engineer to perform a full seismic analysis and design of a liquid-containing structure. This meant that these procedures should cover both aspects of seismic design: the “loading side” (namely the determination of the seismic loads based on the mapped maximum considered earthquake spectral response accelerations at short periods (Ss) and 1 second (S1) obtained from the Seismic Ground Motion maps [Fig. 22-1 through 22-14 of ASCE 7-05, Chapter 22] and the geometry of the structure); and the “resistance side” (the detailed design of the structure in accordance with the provisions of ACI 350, so as to resist those loads safely); and 2. To establish the scope of the new procedures consistent with the overall scope of ACI 350. This required the inclusion of all types of tanks—rectangular, as well as circular; and reinforced concrete, as well as prestressed. (Note: While there are currently at least two national standards that provide detailed procedures for the seismic analysis and design of liquid-containing structures (ANSI/AWWA 1995a,b), these are limited to circular, prestressed concrete tanks only). As the loading side of seismic design is outside the scope of ACI 318, Chapter 21, it was decided to maintain this practice in ACI 350 as well. Accordingly, the basic scope, format, and mandatory language of Chapter 21 of ACI 318 were retained with only enough revisions to adapt the chapter to environmental engineering structures. Provisions similar to Section 1.1.8 of ACI 318 are included in ACI 350. This approach offers at least two advantages: 1. It allows ACI 350 to maintain ACI 318’s practice of limiting its seismic design provisions to the resistance side only; and 2. It makes it easier to update these seismic provisions so as to keep up with the frequent changes and improvements in the field of seismic hazard analysis and evaluation. The seismic force levels and R-factors included in this standard provide results at strength levels, such as those included for seismic design in the 2003 International Building Code (IBC), particularly the applicable connection provisions of 2003 IBC, as referenced in ASCE 7-02. When comparing these provisions with other documents defining seismic forces at allowable stress levels (for example, the 1994 Uniform Building Code [UBC] or ACI 350.3-01), the seismic forces in this standard should be reduced by the applicable factors to derive comparable forces at allowable stress levels. The user should note the following general design methods used in this standard, which represent some of the key differences relative to traditional methodologies, such as those described in ASCE (1984): 1. Instead of assuming a rigid tank for which the acceleration is equal to the ground acceleration at all locations, this staThe following editions for this book are also available...This book also exists in the following packages...About ACIFounded in 1904 and headquartered in Farmington Hills, Michigan, USA, the American Concrete Institute is a leading authority and resource worldwide for the development and distribution of consensus-based standards, technical resources, educational & training programs, certification programs, and proven expertise for individuals and organizations involved in concrete design, construction, and materials, who share a commitment to pursuing the best use of concrete. ACI has over 95 chapters, 110 student chapters, and nearly 20,000 members spanning over 120 countries. |
GROUPS
|